Back to results

University of Ottawa (Canada)

Two-phase closed thermosyphon with two-fluid mixtures.

Abstract

dc:description

An experimental study was conducted to investigate the performance of stationary two-phase closed thermosyphons with two-fluid mixtures. Three mixtures were used as the working fluids: (1) water-ethanol, (2) water-ethyleneglycol and (3) water-glycerol. The results are presented to show the effects of ratio of two fluid component, mean operating temperature, different fluid mixtures, heat flux and inclination of the thermosyphon with respect to the direction of the gravitational force. An analytical model is presented to predict the variation of the overall heat transfer coefficients with mole fraction for the thermosyphon with binary mixtures. A good agreement between the prediction by the model and the experimental results was obtained.

Degree

thesis:*
Grantor dc:publisher
University of Ottawa (Canada)
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Park, Rohjoon.
Contributors dc:contributor
  • Lee, Y.,

Subjects

dc:subject × 1

Identifiers

dc:identifier.*
Identifier
Source: Masters Abstracts International, Volume: 34-02, page: 0860.
9780612005631
http://dx.doi.org/10.20381/ruor-15458
OAI identifier oai:identifier
oai:ruor.uottawa.ca:10393/7685

Chain of custody

source
Harvested from
University of Ottawa
Base URL
ruor.uottawa.ca/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation