Back to results

The Ohio State University

Effect of Mini-implant Diameters on Primary Stability and Viscoelastic Migration of Mini-implants under Orthodontic Loading

Abstract

dc:description

Objectives The objectives of the current study were to examine effects of mini-implant diameters on 1) primary stability and 2) time-dependent migration of mini-implant systems under a tangential loading.Materials and Methods Twenty one mini-implants (7 for each 1.4 mm, 1.6 mm, and 2 mm diameter mini-implant) were placed in mandibular sections of human cadavers (4 males and 3 females, 69.7+/-13.1 years). All mini-implants were 8 mm in length. A tangential load of 2N was applied to the mini-implant in bone under hydration for 2 hours. Migration was assessed as the change in displacement during initial loading followed by 2 hours constant loading. Mean and standard deviation (SD) of bone mineral density (BMD) were obtained using histogram of cone-beam computed tomography (CBCT) attenuation values surrounding the mini-implant hole. The cortical thickness along with the miniscrew hole was also measured using the CBCT image. Results The mini-implant diameters did not have an effect on determining the primary stability and migration of mini-implant (p=0.147). Positive correlations of migration with SD and COV were found (p=0.073). These correlations were independent of the mini-implant diameters (ANCOVA, p=0.11). Conclusions Time-dependent viscoelastic creep migration following the static displacement at the small level of orthodontic constant loading suggested that more complications may be produced due to the micromotion at the immediate loading after implantation.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Dentistry
Grantor dc:publisher
The Ohio State University
Year dc:date
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lee, Jim Ming-An
Contributors dc:contributor
  • Kim, Do-Gyoon

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:etd.ohiolink.edu:osu1365079269

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Lee, Jim Ming-An. Effect of Mini-implant Diameters on Primary Stability and Viscoelastic Migration of Mini-implants under Orthodontic Loading. masters thesis, The Ohio State University, 2013. http://rave.ohiolink.edu/etdc/view?acc_num=osu1365079269