{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1357269157"},"canonical_url":"https://search.dev.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1357269157","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"De-noising of Real-time Dynamic Magnetic Resonance Images by the Combined Application of Karhunen-Loeve Transform (KLT) and Wavelet Filtering","abstract":"A hybrid filtering method called Karhunen Loeve Transform-Wavelet (KW) filtering is presented to de-noise dynamic cardiac magnetic resonance images that simultaneously takes advantage of the intrinsic spatial and temporal redundancies of real-time cardiac cine. This new image filtering technique combines two well-established methods: temporal Karhunen-Loeve transform (KLT) and spatial adaptive wavelet filtering. KW filtering has four steps: 1. Apply KLT along the temporal direction, generating a series of “eigenimages”. Because of the high temporal correlations, most of the energy is concentrated into a few eigenimages. 2. Marcenko-Pastur (MP) law is used to identify and discard the noise-only eigenimages; 3. 2-D spatial wavelet filter with adaptive threshold is applied to each eigenimage. An adaptive threshold is used to define the wavelet filter strength for each of the eigenimages based on the noise variance and standard deviation of the signal, resulting in stronger filtering of the eigenimages that primarily contain noise. 4. Apply the inverse KLT to the filtered eigenimages to generate a new series of cine images with reduced image noise. KW filter was compared with 2 other filters – Spatial Wavelet filter and Temporal KLT filter in terms of SNR gain and edge sharpness. For four volunteer data acquired using rate 5 acceleration, KW filter showed an SNR gain of 98%. For a matched value of SNR gain between KW filter, Wavelet filter and KLT filter, KW filter preserved 93.83% of original image sharpness while Wavelet filter and KLT filter preserved 82.23% and 88.05% respectively.","abstract_html":"A hybrid filtering method called Karhunen Loeve Transform-Wavelet (KW) filtering is presented to de-noise dynamic cardiac magnetic resonance images that simultaneously takes advantage of the intrinsic spatial and temporal redundancies of real-time cardiac cine. This new image filtering technique combines two well-established methods: temporal Karhunen-Loeve transform (KLT) and spatial adaptive wavelet filtering. KW filtering has four steps: 1. Apply KLT along the temporal direction, generating a series of “eigenimages”. Because of the high temporal correlations, most of the energy is concentrated into a few eigenimages. 2. Marcenko-Pastur (MP) law is used to identify and discard the noise-only eigenimages; 3. 2-D spatial wavelet filter with adaptive threshold is applied to each eigenimage. An adaptive threshold is used to define the wavelet filter strength for each of the eigenimages based on the noise variance and standard deviation of the signal, resulting in stronger filtering of the eigenimages that primarily contain noise. 4. Apply the inverse KLT to the filtered eigenimages to generate a new series of cine images with reduced image noise. KW filter was compared with 2 other filters – Spatial Wavelet filter and Temporal KLT filter in terms of SNR gain and edge sharpness. For four volunteer data acquired using rate 5 acceleration, KW filter showed an SNR gain of 98%. For a matched value of SNR gain between KW filter, Wavelet filter and KLT filter, KW filter preserved 93.83% of original image sharpness while Wavelet filter and KLT filter preserved 82.23% and 88.05% respectively.","abstract_has_math":false,"creators":["Palaniappan, Prashanth"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["Simonetti, Orlando P."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-05-21","date_published":"2013-05-21","updated_at":"2026-07-24T03:36:08Z","subjects":["Electrical Engineering","Noise reduction","SNR","Image Processing","MRI"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1357269157","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Simonetti, Orlando P."]},{"key":"dc:creator","label":"Author","values":["Palaniappan, Prashanth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-05-21"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering","Noise reduction","SNR","Image Processing","MRI"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1357269157"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A hybrid filtering method called Karhunen Loeve Transform-Wavelet (KW) filtering is presented to de-noise dynamic cardiac magnetic resonance images that simultaneously takes advantage of the intrinsic spatial and temporal redundancies of real-time cardiac cine. This new image filtering technique combines two well-established methods: temporal Karhunen-Loeve transform (KLT) and spatial adaptive wavelet filtering. KW filtering has four steps: 1. Apply KLT along the temporal direction, generating a series of “eigenimages”. Because of the high temporal correlations, most of the energy is concentrated into a few eigenimages. 2. Marcenko-Pastur (MP) law is used to identify and discard the noise-only eigenimages; 3. 2-D spatial wavelet filter with adaptive threshold is applied to each eigenimage. An adaptive threshold is used to define the wavelet filter strength for each of the eigenimages based on the noise variance and standard deviation of the signal, resulting in stronger filtering of the eigenimages that primarily contain noise. 4. Apply the inverse KLT to the filtered eigenimages to generate a new series of cine images with reduced image noise. KW filter was compared with 2 other filters – Spatial Wavelet filter and Temporal KLT filter in terms of SNR gain and edge sharpness. For four volunteer data acquired using rate 5 acceleration, KW filter showed an SNR gain of 98%. For a matched value of SNR gain between KW filter, Wavelet filter and KLT filter, KW filter preserved 93.83% of original image sharpness while Wavelet filter and KLT filter preserved 82.23% and 88.05% respectively."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.72","1.71 MB"]},{"key":"dc:title","label":"Title","values":["De-noising of Real-time Dynamic Magnetic Resonance Images by the Combined Application of Karhunen-Loeve Transform (KLT) and Wavelet Filtering"]}]}],"canonical_facts":{"dc:contributor":["Simonetti, Orlando P."],"dc:creator":["Palaniappan, Prashanth"],"dc:date":["2013-05-21"],"dc:description":["A hybrid filtering method called Karhunen Loeve Transform-Wavelet (KW) filtering is presented to de-noise dynamic cardiac magnetic resonance images that simultaneously takes advantage of the intrinsic spatial and temporal redundancies of real-time cardiac cine. This new image filtering technique combines two well-established methods: temporal Karhunen-Loeve transform (KLT) and spatial adaptive wavelet filtering. KW filtering has four steps: 1. Apply KLT along the temporal direction, generating a series of “eigenimages”. Because of the high temporal correlations, most of the energy is concentrated into a few eigenimages. 2. Marcenko-Pastur (MP) law is used to identify and discard the noise-only eigenimages; 3. 2-D spatial wavelet filter with adaptive threshold is applied to each eigenimage. An adaptive threshold is used to define the wavelet filter strength for each of the eigenimages based on the noise variance and standard deviation of the signal, resulting in stronger filtering of the eigenimages that primarily contain noise. 4. Apply the inverse KLT to the filtered eigenimages to generate a new series of cine images with reduced image noise. KW filter was compared with 2 other filters – Spatial Wavelet filter and Temporal KLT filter in terms of SNR gain and edge sharpness. For four volunteer data acquired using rate 5 acceleration, KW filter showed an SNR gain of 98%. For a matched value of SNR gain between KW filter, Wavelet filter and KLT filter, KW filter preserved 93.83% of original image sharpness while Wavelet filter and KLT filter preserved 82.23% and 88.05% respectively."],"dc:format":["application/pdf","p.72","1.71 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1357269157"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Electrical Engineering","Noise reduction","SNR","Image Processing","MRI"],"dc:title":["De-noising of Real-time Dynamic Magnetic Resonance Images by the Combined Application of Karhunen-Loeve Transform (KLT) and Wavelet Filtering"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-07-24T03:36:08Z"}