Back to results

Old Dominion University

The Effects of Instrument Handle Design on Forearm Muscle Activity During Scaling by Dental Hygienists

Abstract

dc:description.abstract

<p>Purpose: The purpose of this study was to determine the effects of 4 different commercially available instrument handle designs (A. 16 grams and 12.7 mm diameter; B. 23 grams and 11.1 mm diameter; C. 21 grams and 7.9 mm diameter; D. 18 grams and 6.35 mm diameter) on the muscle activity of four forearm muscles during a simulated scaling experience. Methods: A convenience sample of 27 dental hygienists used a Columbia 13/14 curet with four different instrument handles to scale artificial calculus. While scaling, each participant’s muscle activity was measured using surface electromyography (sEMG). Participants completed an end user opinion survey. Results: Similar muscle activity was generated when scaling with instruments at 16, 18, and 21 grams with varying diameter handles. Instrument B generated significantly more muscle activity when compared to each of the other 3 instrument handle designs (p=0.001, p=0.002, p=0.039). Additionally, the lower left quadrant displayed significantly less muscle activity during scaling than the right quadrants (p=0.026, p=0.000), although no significant interaction effect was found with instruments within quadrants. Most participants (62.96%) preferred instrument A, which was rated more comfortable based on weight when compared to the other instruments tested (z=2.643, p=0.008; z=3.708, p=0.000; z=3.819, p=0.000). The smallest diameter instrument was rated significantly less comfortable (A. z=4.398, p=0.000; B. z=4.023,p=0.000; C. z=3.333, p=0.001). Conclusions: Instrument handle design has a significant effect on forearm muscle activity when performing scaling in a simulated environment. The heaviest instrument produced the highest muscle activity. Similar amounts of muscle activity were produced by instruments weighing between 16 and 21 g. Participants’ instrument preferences were more affected by handle diameter than weight. The need for further research is needed to determine the impact of these results on arm muscle load related to risk of cumulative trauma disorders in a real-world setting.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science in Dental Hygiene (MSDH)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Dental Hygiene
Year dc:date.available
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Suedbeck, Jessica Rae
Contributors dc:contributor
  • Susan Lynn Tolle
  • Gayle McCombs
  • Martha Walker

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • <p>In Copyright. URI: <a href="http://rightsstatements.org/vocab/InC/1.0/">http://rightsstatements.org/vocab/InC/1.0/</a> This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).</p>

Identifiers

dc:identifier.*
Identifier
9781339947266
OAI identifier oai:identifier
oai:digitalcommons.odu.edu:dentalhygiene_etds-1001

Chain of custody

source
Harvested from
Old Dominion University
Base URL
digitalcommons.odu.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Suedbeck, Jessica Rae. The Effects of Instrument Handle Design on Forearm Muscle Activity During Scaling by Dental Hygienists. Thesis thesis, 2016. https://digitalcommons.odu.edu/dentalhygiene_etds/2