{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/43846"},"canonical_url":"https://search.dev.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/43846","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"An Experimental Investigation into NOx Control of a Gas Turbine Combustor and Augmentor Tube Incorporating a Catalytic Reduction System","abstract":"An initial experimental investigation was conducted to examine the feasibility of NO x emission control using catalytic reduction techniques in the jet engine test cell environment. A modified T-63 gas turbine combustor and an augmentor tube, 21 feet in length and containing a perlite catalyst, were used as a gas generator and catalytic reduction system. Four data runs were made. Three runs were completed without the catalyst installed. Temperature and velocity profile measurements were obtained in order to calculate augmentation ratios for different engine fuel to air ratios. NOx, CO, and unburned hydrocarbon concentrations in the exhaust were measured to provide a baseline for further tests. A fourth data run was made with the perlite catalyst installed in the augmentor tube. A 64 percent NOx reduction was observed, however, the large pressure drop across the catalytic bed deemed the current configuration impractical Recommendations for alternative configurations are presented. The results of the investigation have proven that further study is warranted.","abstract_html":"An initial experimental investigation was conducted to examine the feasibility of NO x emission control using catalytic reduction techniques in the jet engine test cell environment. A modified T-63 gas turbine combustor and an augmentor tube, 21 feet in length and containing a perlite catalyst, were used as a gas generator and catalytic reduction system. Four data runs were made. Three runs were completed without the catalyst installed. Temperature and velocity profile measurements were obtained in order to calculate augmentation ratios for different engine fuel to air ratios. NOx, CO, and unburned hydrocarbon concentrations in the exhaust were measured to provide a baseline for further tests. A fourth data run was made with the perlite catalyst installed in the augmentor tube. A 64 percent NOx reduction was observed, however, the large pressure drop across the catalytic bed deemed the current configuration impractical Recommendations for alternative configurations are presented. The results of the investigation have proven that further study is warranted.","abstract_has_math":false,"creators":["Behrens, Christopher Karl"],"institution":"Monterey, California: Naval Postgraduate School.","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Department of Aeronautics and Astronautics","school":null,"contributors":[],"advisors":["Netzer, D.W."],"committee_chairs":[],"committee_members":[],"year":1990,"date_issued":"1990-03","date_published":"1990-03","updated_at":"2026-07-27T20:26:50Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/43846","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Netzer, D.W."]},{"key":"dc:contributor.department","label":"Department","values":["Department of Aeronautics and Astronautics"]},{"key":"dc:creator","label":"Author","values":["Behrens, Christopher Karl"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["Mar 1990"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-12-01T19:28:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-12-01T19:28:18Z"]},{"key":"dc:date.issued","label":"Date","values":["1990-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California: Naval Postgraduate School."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/43846"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An initial experimental investigation was conducted to examine the feasibility of NO x emission control using catalytic reduction techniques in the jet engine test cell environment. A modified T-63 gas turbine combustor and an augmentor tube, 21 feet in length and containing a perlite catalyst, were used as a gas generator and catalytic reduction system. Four data runs were made. Three runs were completed without the catalyst installed. Temperature and velocity profile measurements were obtained in order to calculate augmentation ratios for different engine fuel to air ratios. NOx, CO, and unburned hydrocarbon concentrations in the exhaust were measured to provide a baseline for further tests. A fourth data run was made with the perlite catalyst installed in the augmentor tube. A 64 percent NOx reduction was observed, however, the large pressure drop across the catalytic bed deemed the current configuration impractical Recommendations for alternative configurations are presented. The results of the investigation have proven that further study is warranted."]},{"key":"dc:title","label":"Title","values":["An Experimental Investigation into NOx Control of a Gas Turbine Combustor and Augmentor Tube Incorporating a Catalytic Reduction System"]}]}],"canonical_facts":{"dc:contributor.advisor":["Netzer, D.W."],"dc:contributor.department":["Department of Aeronautics and Astronautics"],"dc:creator":["Behrens, Christopher Karl"],"dc:date":["Mar 1990"],"dc:date.accessioned":["2014-12-01T19:28:18Z"],"dc:date.available":["2014-12-01T19:28:18Z"],"dc:date.issued":["1990-03"],"dc:description.abstract":["An initial experimental investigation was conducted to examine the feasibility of NO x emission control using catalytic reduction techniques in the jet engine test cell environment. A modified T-63 gas turbine combustor and an augmentor tube, 21 feet in length and containing a perlite catalyst, were used as a gas generator and catalytic reduction system. Four data runs were made. Three runs were completed without the catalyst installed. Temperature and velocity profile measurements were obtained in order to calculate augmentation ratios for different engine fuel to air ratios. NOx, CO, and unburned hydrocarbon concentrations in the exhaust were measured to provide a baseline for further tests. A fourth data run was made with the perlite catalyst installed in the augmentor tube. A 64 percent NOx reduction was observed, however, the large pressure drop across the catalytic bed deemed the current configuration impractical Recommendations for alternative configurations are presented. The results of the investigation have proven that further study is warranted."],"dc:identifier.uri":["https://hdl.handle.net/10945/43846"],"dc:publisher":["Monterey, California: Naval Postgraduate School."],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"dc:title":["An Experimental Investigation into NOx Control of a Gas Turbine Combustor and Augmentor Tube Incorporating a Catalytic Reduction System"],"dc:type":["Thesis"]},"updated_at":"2026-07-27T20:26:50Z"}