{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/23887"},"canonical_url":"https://search.dev.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/23887","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Evaluation of a user information satisfaction short-form instrument","abstract":"The objectives of this thesis were to validate and evaluate the Barousi and Orlikowski (2) short-form UIS instrument as a surrogate measurement of effectiveness of the Department of Defense's Composite Health Care System (CHCS).Hurd (1), using the short-form UIS instrument at the Naval Hospital, Charleston, suggested that a fundamental change in the instrument's structure due to significant impact of the contractor's services with the CHCS. The three Navy CHCS operational testing and evaluation were used in this study. The short-form instrument was found to be inadequate for evaluation of overall UIS of the CHCS. Limitations found were: a fundamental change in the factor structure; unevenly distributed variables in a couple of factors; low reliability in one factor; no assessment of user interface with the system; and inconsistent convergent validity findings. A proposed re-design is presented. Statistically significant differences in UIS between groups and sites were found for the four factor solution. Participants were divided into three functional user groups: Physicians, Medical Support and Administrative Support. All three groups were satisfied with the local Management Information Department staff and services and the system's output, All three groups were dissatisfied with the contractor services. Physicians were significantly less satisfied in three out of the four factors. No significant correlation between time of use of the system and UIS was found, except for the Administrative group's positive correlation with the system's output.","abstract_html":"The objectives of this thesis were to validate and evaluate the Barousi and Orlikowski (2) short-form UIS instrument as a surrogate measurement of effectiveness of the Department of Defense&#x27;s Composite Health Care System (CHCS).Hurd (1), using the short-form UIS instrument at the Naval Hospital, Charleston, suggested that a fundamental change in the instrument&#x27;s structure due to significant impact of the contractor&#x27;s services with the CHCS. The three Navy CHCS operational testing and evaluation were used in this study. The short-form instrument was found to be inadequate for evaluation of overall UIS of the CHCS. Limitations found were: a fundamental change in the factor structure; unevenly distributed variables in a couple of factors; low reliability in one factor; no assessment of user interface with the system; and inconsistent convergent validity findings. A proposed re-design is presented. Statistically significant differences in UIS between groups and sites were found for the four factor solution. Participants were divided into three functional user groups: Physicians, Medical Support and Administrative Support. All three groups were satisfied with the local Management Information Department staff and services and the system&#x27;s output, All three groups were dissatisfied with the contractor services. Physicians were significantly less satisfied in three out of the four factors. No significant correlation between time of use of the system and UIS was found, except for the Administrative group&#x27;s positive correlation with the system&#x27;s output.","abstract_has_math":false,"creators":["Lockhart, Mark S."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Department of Administrative Sciences","school":null,"contributors":[],"advisors":["Zviran, Moshe","Sengupta, Kishore Sen"],"committee_chairs":[],"committee_members":[],"year":1992,"date_issued":"1992-03","date_published":"1992-03","updated_at":"2026-07-27T20:25:31Z","subjects":[],"languages":["en_US"],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/23887","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zviran, Moshe","Sengupta, Kishore Sen"]},{"key":"dc:contributor.department","label":"Department","values":["Department of Administrative Sciences"]},{"key":"dc:creator","label":"Author","values":["Lockhart, Mark S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["March 1992"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-29T16:18:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-29T16:18:10Z"]},{"key":"dc:date.issued","label":"Date","values":["1992-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/23887"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objectives of this thesis were to validate and evaluate the Barousi and Orlikowski (2) short-form UIS instrument as a surrogate measurement of effectiveness of the Department of Defense's Composite Health Care System (CHCS).Hurd (1), using the short-form UIS instrument at the Naval Hospital, Charleston, suggested that a fundamental change in the instrument's structure due to significant impact of the contractor's services with the CHCS. The three Navy CHCS operational testing and evaluation were used in this study. The short-form instrument was found to be inadequate for evaluation of overall UIS of the CHCS. Limitations found were: a fundamental change in the factor structure; unevenly distributed variables in a couple of factors; low reliability in one factor; no assessment of user interface with the system; and inconsistent convergent validity findings. A proposed re-design is presented. Statistically significant differences in UIS between groups and sites were found for the four factor solution. Participants were divided into three functional user groups: Physicians, Medical Support and Administrative Support. All three groups were satisfied with the local Management Information Department staff and services and the system's output, All three groups were dissatisfied with the contractor services. Physicians were significantly less satisfied in three out of the four factors. No significant correlation between time of use of the system and UIS was found, except for the Administrative group's positive correlation with the system's output."]},{"key":"dc:title","label":"Title","values":["Evaluation of a user information satisfaction short-form instrument"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zviran, Moshe","Sengupta, Kishore Sen"],"dc:contributor.department":["Department of Administrative Sciences"],"dc:creator":["Lockhart, Mark S."],"dc:date":["March 1992"],"dc:date.accessioned":["2012-11-29T16:18:10Z"],"dc:date.available":["2012-11-29T16:18:10Z"],"dc:date.issued":["1992-03"],"dc:description.abstract":["The objectives of this thesis were to validate and evaluate the Barousi and Orlikowski (2) short-form UIS instrument as a surrogate measurement of effectiveness of the Department of Defense's Composite Health Care System (CHCS).Hurd (1), using the short-form UIS instrument at the Naval Hospital, Charleston, suggested that a fundamental change in the instrument's structure due to significant impact of the contractor's services with the CHCS. The three Navy CHCS operational testing and evaluation were used in this study. The short-form instrument was found to be inadequate for evaluation of overall UIS of the CHCS. Limitations found were: a fundamental change in the factor structure; unevenly distributed variables in a couple of factors; low reliability in one factor; no assessment of user interface with the system; and inconsistent convergent validity findings. A proposed re-design is presented. Statistically significant differences in UIS between groups and sites were found for the four factor solution. Participants were divided into three functional user groups: Physicians, Medical Support and Administrative Support. All three groups were satisfied with the local Management Information Department staff and services and the system's output, All three groups were dissatisfied with the contractor services. Physicians were significantly less satisfied in three out of the four factors. No significant correlation between time of use of the system and UIS was found, except for the Administrative group's positive correlation with the system's output."],"dc:identifier.uri":["https://hdl.handle.net/10945/23887"],"dc:language.iso":["en_US"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"dc:title":["Evaluation of a user information satisfaction short-form instrument"],"dc:type":["Thesis"]},"updated_at":"2026-07-27T20:25:31Z"}