Monterey, California. Naval Postgraduate School
Investigation of gravitational effects on the performance of variable conductance heat pipe.
Abstract
dc:description.abstractA variable conductance heat pipe with a length to diameter ratio of 96 to 1 was designed and constructed. The performance characteristics of both the conventional and gas loaded variable conductance modes of operation were studied. Particular emphasis was placed upon investigating the gravitational effects in the variable conductance mode. Heat inputs were varied from ten to fifty watts for horizontal and vertical operating positions. Methanol was used as the working fluid with either helium or krypton used as the non-condensible gas. Condenser temperature profiles and liquid crystal pictures, showing the effects of gravity, are presented for the various operating modes.
Degree
thesis:*- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- Monterey, California. Naval Postgraduate School
- Year dc:date.issued
- 1973
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Humphreys, Wayne Ives
- Advisor dc:contributor.advisor
-
- Kelleher, Matthew
Rights
dc:rights- Statement dc:rights
-
- This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.