{"id":{"repo_id":"njit","oai_identifier":"oai:digitalcommons.njit.edu:theses-1383"},"canonical_url":"https://search.dev.ndltd.org/etd/njit/oai:digitalcommons.njit.edu:theses-1383","repository":{"repo_id":"njit","name":"NJIT","base_url":"https://digitalcommons.njit.edu/do/oai/"},"display":{"title":"Inverse solid-liquid fluidization of aerogel granules and its application in removing oil from water","abstract":"Fluidization is a very well known unit operation used in the chemical industry for various purposes. Inverse solid-liquid fluidization, where the solid particles to be fluidized are less dense than the fluid, is one of the several different kinds of fluidization being studied for its potential in industrial applications. The present work focuses on finding the hydrodynamic characteristics (minimum fluidization velocity, bed expansion and pressure drop) of an inverse fluidized bed of aerogel granules and using this system to remove oil from an oil-water mixture. The solid particles employed for this study are low density (100 kg/m^3) surface treated hydrophobic aerogel (Nanogel ) granules of size in the range of 0.5 to 2.3 mm. These particles are highly porous characterized by a nanosized pore structure and a very high surface area. Since their density is lower than water, they are fluidized downward in a solid-liquid inverse fluidized bed column. In this work, a constant flow of an oil-water mixture is passed through an inverse fluidized bed of aerogel granules. The oil concentration was determined by measuring the Chemical Oxygen Demand (COD) using a colorimeter. Once the aerogel granules are saturated, they were entrained from the fluidized bed, and separated from the clean stream of water with a fibrous filter.","abstract_html":"Fluidization is a very well known unit operation used in the chemical industry for various purposes. Inverse solid-liquid fluidization, where the solid particles to be fluidized are less dense than the fluid, is one of the several different kinds of fluidization being studied for its potential in industrial applications. The present work focuses on finding the hydrodynamic characteristics (minimum fluidization velocity, bed expansion and pressure drop) of an inverse fluidized bed of aerogel granules and using this system to remove oil from an oil-water mixture. The solid particles employed for this study are low density (100 kg/m^3) surface treated hydrophobic aerogel (Nanogel ) granules of size in the range of 0.5 to 2.3 mm. These particles are highly porous characterized by a nanosized pore structure and a very high surface area. Since their density is lower than water, they are fluidized downward in a solid-liquid inverse fluidized bed column. In this work, a constant flow of an oil-water mixture is passed through an inverse fluidized bed of aerogel granules. The oil concentration was determined by measuring the Chemical Oxygen Demand (COD) using a colorimeter. Once the aerogel granules are saturated, they were entrained from the fluidized bed, and separated from the clean stream of water with a fibrous filter.","abstract_has_math":false,"creators":["Patel, Gaurav Babubhai"],"institution":null,"degree_name":"Master of Science in Chemical Engineering - (M.S.)","degree_level":null,"degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":["Robert Pfeffer","Rajesh N. Dave","Michael Chien-Yueh Huang"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-01-31T08:00:00Z","date_published":"2007-01-31T08:00:00Z","updated_at":"2026-07-24T03:23:22Z","subjects":["Fluidization","Inverse fluidized bed","Aerogel granules","Oil removal","Chemical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.njit.edu/theses/384","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Robert Pfeffer","Rajesh N. Dave","Michael Chien-Yueh Huang"]},{"key":"dc:creator","label":"Author","values":["Patel, Gaurav Babubhai"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Chemical Engineering - (M.S.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fluidization","Inverse fluidized bed","Aerogel granules","Oil removal","Chemical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.njit.edu/theses/384"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Fluidization is a very well known unit operation used in the chemical industry for various purposes. Inverse solid-liquid fluidization, where the solid particles to be fluidized are less dense than the fluid, is one of the several different kinds of fluidization being studied for its potential in industrial applications. The present work focuses on finding the hydrodynamic characteristics (minimum fluidization velocity, bed expansion and pressure drop) of an inverse fluidized bed of aerogel granules and using this system to remove oil from an oil-water mixture. The solid particles employed for this study are low density (100 kg/m^3) surface treated hydrophobic aerogel (Nanogel ) granules of size in the range of 0.5 to 2.3 mm. These particles are highly porous characterized by a nanosized pore structure and a very high surface area. Since their density is lower than water, they are fluidized downward in a solid-liquid inverse fluidized bed column. In this work, a constant flow of an oil-water mixture is passed through an inverse fluidized bed of aerogel granules. The oil concentration was determined by measuring the Chemical Oxygen Demand (COD) using a colorimeter. Once the aerogel granules are saturated, they were entrained from the fluidized bed, and separated from the clean stream of water with a fibrous filter."]},{"key":"dc:title","label":"Title","values":["Inverse solid-liquid fluidization of aerogel granules and its application in removing oil from water"]}]}],"canonical_facts":{"dc:contributor":["Robert Pfeffer","Rajesh N. Dave","Michael Chien-Yueh Huang"],"dc:creator":["Patel, Gaurav Babubhai"],"dc:description.abstract":["Fluidization is a very well known unit operation used in the chemical industry for various purposes. Inverse solid-liquid fluidization, where the solid particles to be fluidized are less dense than the fluid, is one of the several different kinds of fluidization being studied for its potential in industrial applications. The present work focuses on finding the hydrodynamic characteristics (minimum fluidization velocity, bed expansion and pressure drop) of an inverse fluidized bed of aerogel granules and using this system to remove oil from an oil-water mixture. The solid particles employed for this study are low density (100 kg/m^3) surface treated hydrophobic aerogel (Nanogel ) granules of size in the range of 0.5 to 2.3 mm. These particles are highly porous characterized by a nanosized pore structure and a very high surface area. Since their density is lower than water, they are fluidized downward in a solid-liquid inverse fluidized bed column. In this work, a constant flow of an oil-water mixture is passed through an inverse fluidized bed of aerogel granules. The oil concentration was determined by measuring the Chemical Oxygen Demand (COD) using a colorimeter. Once the aerogel granules are saturated, they were entrained from the fluidized bed, and separated from the clean stream of water with a fibrous filter."],"dc:identifier":["https://digitalcommons.njit.edu/theses/384"],"dc:subject":["Fluidization","Inverse fluidized bed","Aerogel granules","Oil removal","Chemical Engineering"],"dc:title":["Inverse solid-liquid fluidization of aerogel granules and its application in removing oil from water"],"dc:type":["Thesis"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_name":["Master of Science in Chemical Engineering - (M.S.)"]},"updated_at":"2026-07-24T03:23:22Z"}