Back to results

NJIT

Biomechanical testing of upright range of motion versus overhead supine range of motion

Abstract

dc:description.abstract

Rehabilitation of an elbow, following injury, is not a well-studied subject. Clinically, there is not a general consensus on which recovery method is optimal for healing an unstable elbow. When dealing with medial collateral ligament deficiency, many authors have proposed several forearm positions that will yield proper healing of the unstable elbow. Some researchers believe that active mobilization of the elbow with the arm in a vertical position is a safe protocol for rehabilitation with the forearm oriented in a supine pronated position. It was also mentioned that the compressive forces due to the active mobilization of the arm will stabilize the MCL deficient elbow'. This study is unique in that the proposal is that supine overhead range of motion will stabilize the MCL deficient elbow because gravity will act as a compressive force keeping the MCL deficient elbow intact. In this study, the gravitational stabilizing factor will be demonstrated comparing both the supine overhead range of motion and the commonly used upright range of motion protocol. The hypothesis is that supine overhead range of motion provides stability to a collateral deficient elbow. Moreover, supine overhead range of motion is a superior way to rehabilitate an unstable elbow because the forces of gravity hold the elbow in concentric reduction rather than distracting the elbow joint when the forearm is rehabilitated in an upright manner. The overhead ROM provided more stability to the unstable elbow, more especially to the elbows with the AC still intact.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Biomedical Engineering - (M.S.)
Discipline thesis:degree_discipline
Biomedical Engineering
Year
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Uko, Linda
Contributors dc:contributor
  • Virak Tan
  • Richard A. Foulds
  • Sergei Adamovich

Subjects

dc:subject × 5

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.njit.edu/theses/374
OAI identifier oai:identifier
oai:digitalcommons.njit.edu:theses-1373

Chain of custody

source
Harvested from
NJIT
Base URL
digitalcommons.njit.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Uko, Linda. Biomechanical testing of upright range of motion versus overhead supine range of motion. 2008. https://digitalcommons.njit.edu/theses/374