Back to results

NJIT

Photoplethysmorgraph-derived respiration

Abstract

dc:description.abstract

Stress & Motivated Behavioral Institute (SMBI) has developed a research program to provide an objective evaluation of the physiological and neurocognitive impact of human electromuscular muscular interference (HEMI) devices in humans. The initial step is to understand their physiological impact, which is characterized by vital signs. Volunteers are recruited from HEMI training programs with the provision that data collection can not interfere with training. Thus, an ambulatory system was assembled. There are two main issues in the current ambulatory system, one of which is the reliability of the respiration signal obtained using a strain gauge respiration band, mainly due to motion artifact. The field of monitoring heart rate and respiratory rate using the photoplethysmograph (PPG) signal is rapidly growing. The main objectives of the thesis is to design a PPG hardware an ear clip sensor and analog processing circuit -- to comprise respiration related information and build a software using autoregressive modeling technique to extract respiratory rate from the PPG signal. The custom hardware and software verification results are compared with that of off-the-shelf Nonin pulse oximetry module -- Xpod. The custom hardware PPG signal was affected more significantly by motion artifact than the Xpod hardware output. Discrepancies in detecting 6 breaths per minute using custom PPG signal were noted. In conclusion, a few changes in the custom hardware circuit are suggested to further improve the software results in an ambulatory setting. In addition, a more controlled study is suggested.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Biomedical Engineering - (M.S.)
Discipline thesis:degree_discipline
Biomedical Engineering
Year
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Shah, Priyanka Pankaj
Contributors dc:contributor
  • Lisa K. Simone
  • Michael T. Bergen
  • Ali N. Akansu

Subjects

dc:subject × 4

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.njit.edu/theses/369
OAI identifier oai:identifier
oai:digitalcommons.njit.edu:theses-1368

Chain of custody

source
Harvested from
NJIT
Base URL
digitalcommons.njit.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Shah, Priyanka Pankaj. Photoplethysmorgraph-derived respiration. 2008. https://digitalcommons.njit.edu/theses/369