Hydrodynamic effects of a cannula in a USP dissolution testing apparatus 2

Abstract

dc:description.abstract

Dissolution testing is routinely used in the pharmaceutical industry to provide in vitro drug release information for drug development and quality control purposes. The USP Testing Apparatus 2 is the most common dissolution testing system for solid dosage forms. Usually, sampling cannulas are used to take samples manually from the dissolution medium. However, the inserted cannula can alter the normal fluid flow within the vessel and produce different dissolution testing results. The hydrodynamic effects introduced by a permanently inserted cannula in a USP Dissolution Testing Apparatus 2 were evaluated by two approaches. Firstly, the dissolution tests were conducted with two dissolution systems, the testing system (with cannula) and the standard system (without cannula), for nine different tablet positions using non-disintegrating salicylic acid calibrator tablets. The dissolution profiles at each tablet location in the two systems were compared using statistical tools. Secondly, Particle Image Velocimetry (PIV) was used to obtain experimentally velocity vector maps and velocity profiles in the vessel for the two systems and to quantify changes in the velocities on selected horizontal so-surfaces. The results show that the system with the cannula produced higher dissolution profiles than that without the cannula and that the magnitude of the difference between dissolution profiles in the two systems depended on tablet location. However, in most dissolution tests, the changes in dissolution profile due to the cannula were small enough to satisfy the FDA criteria for similarity between dissolution profiles (f_1 and f_2 values). PIV measurements showed slightly changes in the velocities of the fluid flow in the vessel where the cannula was inserted. The most significant velocity changes were observed closest to the cannula. However, generally the hydrodynamic effect generated by the cannula did not appear to be particularly strong, which was consistent to dissolution test results. It can be concluded that the hydrodynamic effects generated by the inserted cannula are real and observable. Such effects result in slightly mod fications of the fluid flow in the dissolution vessel and in detectable differences in the dissolution profiles, which, although limited, can introduce variations in test results possibly leading to failure of routine dissolution tests.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Pharmaceutical Engineering - (M.S.)
Discipline thesis:degree_discipline
Chemical, Biological and Pharmaceutical Engineering
Year
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Liu, Qianqian
Contributors dc:contributor
  • Piero M. Armenante
  • Laurent Simon
  • Gerard Bredael

Subjects

dc:subject × 5

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.njit.edu/theses/168
OAI identifier oai:identifier
oai:digitalcommons.njit.edu:theses-1167

Chain of custody

source
Harvested from
NJIT
Base URL
digitalcommons.njit.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Liu, Qianqian. Hydrodynamic effects of a cannula in a USP dissolution testing apparatus 2. 2013. https://digitalcommons.njit.edu/theses/168