Back to results

NJIT

The effect of handle characteristics of a hammer stapler on biomechanical and physiological response

Abstract

dc:description.abstract

Frequent and prolonged use of an improperly designed hand tool not only affects productivity but may also cause painful symptoms which, if left untreated, can develop into chronic musculoskeletal disorders (MSDs). This study was undertaken to assess the effects of ergonomic guidelines related to grip characteristics of a hammer stapler. Specifically, surface composition, shape, and angle of grip were investigated. Three commercially available hammer staplers were selected for this study. Tool #1 had a basic grip design, Tool #2 had a somewhat improved grip design, and Tool #3 incorporated most of the ergonomic design guidelines in terms of grip surface, grip shape, and grip angle. In a laboratory setting, 16 male participants used each of these tools on each of two simulated roof pitches at 4:12 and 6:12 inclines. Each experimental trial consisted of stapling roofing underlayment onto the simulated roof at a frequency of 1 staple per second for a two-minute duration. At a significance level of 5%, Tool #3 produced lower discomfort ratings in fingers and hand and higher favorable ratings for perceived grip comfort and protection from injury. Tool #3 also had significantly lower (p<0.05) muscle EMG in the flexor carpi ulnaris and lower ulnar deviation of the wrist angle at the instant of tool impact. The outcome of this study strongly favors implementation of ergonomic guidelines in hand tool design for non-powered, impact type hand tools. The quantitative results derived from this study would be useful in making design improvements in future hand tool design.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Occupational Safety and Health Engineering - (M.S.)
Discipline thesis:degree_discipline
Mechanical and Industrial Engineering
Year
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Latta, Wayne
Contributors dc:contributor
  • Arijit K. Sengupta
  • Athanassios K. Bladikas
  • George W. Olsen

Subjects

dc:subject × 4

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.njit.edu/theses/58
OAI identifier oai:identifier
oai:digitalcommons.njit.edu:theses-1057

Chain of custody

source
Harvested from
NJIT
Base URL
digitalcommons.njit.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Latta, Wayne. The effect of handle characteristics of a hammer stapler on biomechanical and physiological response. 2010. https://digitalcommons.njit.edu/theses/58