Design of x-ray source for real-time computed tomography

Abstract

dc:description.abstract

<p>"The reduction of motion blur in computed tomography (CT) drives the current research for multisource CT. Due to their compact nature, the current multisource systems utilize stationary angled anodes. Unfortunately, these configurations neither simplify the imaging geometry, nor satisfy the need for managing the high thermal loads demanded by real-time CT (30 acquisition frames per second). To add to the current field of knowledge, two x-ray tube concepts are presented in this dissertation. First, a simulation of transient thermal analysis was performed on a compact transmission-type x-ray tube anode operating in pulse-mode. A correlation was found between deposited beam power and maximum anode temperature for any anode thickness beyond 0.5 mm.</p><p>A second approach was developed for higher current applications: a rotating cylindrical anode. A modified Oosterkamp equation was developed and used to investigate three beam-sweeping sequences. It was found that although increasing beam sweeping speed increased the maximum power, the deposited energy in the focal spot per acquisition time decreased. Ultimately the step-and shoot sequence was found to be optimal for the cylindrical anode. Next, MCNP was used to find the angular dependence of the fraction of energy that the backscattered electrons carry away from the focal spot for a curved anode. That information was then used in COMSOL to find the electron beam efficiency and maximum power for different incident angles using various focal spot lengths and anode diameters. After that a correlation between maximum deposited power, focal spot length, and rotational surface speed was found. Finally, design considerations are reported based upon a sensitivity analysis of a preliminary design for the cylindrical multisource anode"--Abstract, page iii.</p>

Degree

thesis:*
Name thesis:degree_name
Ph. D. in Nuclear Engineering
Grantor
Missouri University of Science and Technology

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tucker, Wesley William

Subjects

dc:subject × 8

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:scholarsmine.mst.edu:doctoral_dissertations-3882

Chain of custody

source
Harvested from
Missouri University of Science and Technology
Base URL
scholarsmine.mst.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Tucker, Wesley William. Design of x-ray source for real-time computed tomography. Missouri University of Science and Technology, https://scholarsmine.mst.edu/doctoral_dissertations/2877