Accurate monitoring of x, y, and z magnetization for analysis of hardware and pulse sequence performance in NMR spectroscopy

Abstract

dc:description.abstract

<p>"A new nuclear magnetic resonance (NMR) imaging protocol has been developed to independently record the x, y, and z components of the nuclear net magnetization at any point in a pulse sequence while eliminating the observation of the other components. This protocol provides an experimental method of tracking magnetization which then can be used in conjunction with theoretical models to scrutinize the predicted outcome of each step in an NMR pulse sequence and potentially find further improvements to their effectiveness and efficiency. The protocol utilizes a rapid rotating-frame imaging pulse-train technique to obtain RF-field (B<sub>1</sub>) and resonance-offset (ΔB<sub>0</sub>) dependent profiles for each Cartesian component in the rotating magnetic coordinate system. The proposed protocol was used to analyze the distribution of the sample as a function of the B<sub>1</sub> field strength in a selective, single-channel <sup>1</sup>H probe as well as a standard, dual-channel broadband probe. Data from both probes show that the magnetization within a sample is exposed to a wide range of B<sub>1</sub> field strength. Hard pulses of varying angles were examined showing that an expected pulse nutation angle, such as a 90° pulse, is only achieved for a very small portion of the sample. The protocol was also used to assess the performance of the widely used inversion-recovery sequence (180° - τ - 90°) for spin-lattice relaxation measurements and to find improvements for the newly developed solvent-suppression sequence EXCEPT. Independently monitoring the magnetization components helped to identify that the remaining solvent-signal intensity after the EXCEPT sequence is linked to portions of the sample located in areas of very low and very high B<sub>1</sub> fields, leading to a targeted approach for improving the EXCEPT sequence"--Abstract, page iii.</p>

Degree

thesis:*
Name thesis:degree_name
Ph. D. in Chemistry
Grantor
Missouri University of Science and Technology

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Schmittzehe, Emmalou Theresa

Subjects

dc:subject × 7

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:scholarsmine.mst.edu:doctoral_dissertations-3853

Chain of custody

source
Harvested from
Missouri University of Science and Technology
Base URL
scholarsmine.mst.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Schmittzehe, Emmalou Theresa. Accurate monitoring of x, y, and z magnetization for analysis of hardware and pulse sequence performance in NMR spectroscopy. Missouri University of Science and Technology, https://scholarsmine.mst.edu/doctoral_dissertations/2848