{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/98756"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/98756","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Removal rates of electrolytes commonly found in brackish groundwater by means of electrodialysis reversal desalination","abstract":"This thesis tested and analyzed the removal rates of six different electrolytes: NaCl, Na2SO4 , MgCl2 , K2SO4 , Ca(NO3 )2, and CaSO4 when using electrodialysis reversal (EDR) desalination. A bench top EDR set-up was designed and built, and this set-up was used to desalinate feed water with initial concentrations of about 1000 ppm of each of the electrolytes. The tests ran until the diluate stream reached a concentration of 415 ppm. These results were then compared to a mathematical model that predicts the electrolyte removal behavior, and the experimental results did align with the model. When the mathematical model was used to estimate the electrolytes' behaviors for beginning concentrations of exactly 900 ppm, it was shown that the ranking of electrolytes with highest to lowest removal rates is NaCl (38.8 ppm/min when the diluate concentration is 415 ppm), K2SO4 (36.0 ppm/min), CaSO4 (33.6 ppm/min), Na2SO4 (33.4 ppm/min), MgCl2 (32.7 ppm/min), and Ca(NO3)2 (31.8 ppm/min).","abstract_html":"This thesis tested and analyzed the removal rates of six different electrolytes: NaCl, Na2SO4 , MgCl2 , K2SO4 , Ca(NO3 )2, and CaSO4 when using electrodialysis reversal (EDR) desalination. A bench top EDR set-up was designed and built, and this set-up was used to desalinate feed water with initial concentrations of about 1000 ppm of each of the electrolytes. The tests ran until the diluate stream reached a concentration of 415 ppm. These results were then compared to a mathematical model that predicts the electrolyte removal behavior, and the experimental results did align with the model. When the mathematical model was used to estimate the electrolytes&#x27; behaviors for beginning concentrations of exactly 900 ppm, it was shown that the ranking of electrolytes with highest to lowest removal rates is NaCl (38.8 ppm/min when the diluate concentration is 415 ppm), K2SO4 (36.0 ppm/min), CaSO4 (33.6 ppm/min), Na2SO4 (33.4 ppm/min), MgCl2 (32.7 ppm/min), and Ca(NO3)2 (31.8 ppm/min).","abstract_has_math":false,"creators":["Van de Zande, Georgia D"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Amos Winter."],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-07-22T22:22:12Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/98756","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Amos Winter."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Van de Zande, Georgia D"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-09-17T19:09:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-09-17T19:09:57Z"]},{"key":"dc:date.issued","label":"Date","values":["2015"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/98756"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis: S.B., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2015.","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 39-40)."]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis tested and analyzed the removal rates of six different electrolytes: NaCl, Na2SO4 , MgCl2 , K2SO4 , Ca(NO3 )2, and CaSO4 when using electrodialysis reversal (EDR) desalination. A bench top EDR set-up was designed and built, and this set-up was used to desalinate feed water with initial concentrations of about 1000 ppm of each of the electrolytes. The tests ran until the diluate stream reached a concentration of 415 ppm. These results were then compared to a mathematical model that predicts the electrolyte removal behavior, and the experimental results did align with the model. When the mathematical model was used to estimate the electrolytes' behaviors for beginning concentrations of exactly 900 ppm, it was shown that the ranking of electrolytes with highest to lowest removal rates is NaCl (38.8 ppm/min when the diluate concentration is 415 ppm), K2SO4 (36.0 ppm/min), CaSO4 (33.6 ppm/min), Na2SO4 (33.4 ppm/min), MgCl2 (32.7 ppm/min), and Ca(NO3)2 (31.8 ppm/min)."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Removal rates of electrolytes commonly found in brackish groundwater by means of electrodialysis reversal desalination"]}]}],"canonical_facts":{"dc:contributor.advisor":["Amos Winter."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Mechanical Engineering."],"dc:creator":["Van de Zande, Georgia D"],"dc:date.accessioned":["2015-09-17T19:09:57Z"],"dc:date.available":["2015-09-17T19:09:57Z"],"dc:date.issued":["2015"],"dc:description":["Thesis: S.B., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2015.","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 39-40)."],"dc:description.abstract":["This thesis tested and analyzed the removal rates of six different electrolytes: NaCl, Na2SO4 , MgCl2 , K2SO4 , Ca(NO3 )2, and CaSO4 when using electrodialysis reversal (EDR) desalination. A bench top EDR set-up was designed and built, and this set-up was used to desalinate feed water with initial concentrations of about 1000 ppm of each of the electrolytes. The tests ran until the diluate stream reached a concentration of 415 ppm. These results were then compared to a mathematical model that predicts the electrolyte removal behavior, and the experimental results did align with the model. When the mathematical model was used to estimate the electrolytes' behaviors for beginning concentrations of exactly 900 ppm, it was shown that the ranking of electrolytes with highest to lowest removal rates is NaCl (38.8 ppm/min when the diluate concentration is 415 ppm), K2SO4 (36.0 ppm/min), CaSO4 (33.6 ppm/min), Na2SO4 (33.4 ppm/min), MgCl2 (32.7 ppm/min), and Ca(NO3)2 (31.8 ppm/min)."],"dc:description.degree":["S.B."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/98756"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Removal rates of electrolytes commonly found in brackish groundwater by means of electrodialysis reversal desalination"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:12Z"}