{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/9329"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/9329","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Development of a chronically implanted microelectrode array for intraneural electrical stimulation for prosthetic sensory feedback","abstract":"The functionality of prosthetic limbs is restricted by the limited availability of sensory feedback. This research aims to develop a technology to allow the presentation of sensory information directly to the sensory afferent neurons of the transected peripheral nerve in the stump of the amputee. lntraneural implants of several designs were developed and implanted in rabbit animal models and monitored for chronic functionality evaluated using both neurophysiological and behavioral tests. Animal studies have demonstrated single channel implant functionality of up to 129 days. The relative merit of the designs is assessed, and future directions for implant design and behavioral testing are suggested.","abstract_html":"The functionality of prosthetic limbs is restricted by the limited availability of sensory feedback. This research aims to develop a technology to allow the presentation of sensory information directly to the sensory afferent neurons of the transected peripheral nerve in the stump of the amputee. lntraneural implants of several designs were developed and implanted in rabbit animal models and monitored for chronic functionality evaluated using both neurophysiological and behavioral tests. Animal studies have demonstrated single channel implant functionality of up to 129 days. The relative merit of the designs is assessed, and future directions for implant design and behavioral testing are suggested.","abstract_has_math":false,"creators":["DiLorenzo, Daniel John"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Harvard University--MIT Division of Health Sciences and Technology.","school":null,"contributors":[],"advisors":["David J. Edell."],"committee_chairs":[],"committee_members":[],"year":1999,"date_issued":"1999","date_published":"1999","updated_at":"2026-07-22T22:22:02Z","subjects":["Harvard University--MIT Division of Health Sciences and Technology."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/9329","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["David J. Edell."]},{"key":"dc:contributor.department","label":"Department","values":["Harvard University--MIT Division of Health Sciences and Technology."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Harvard University--MIT Division of Health Sciences and Technology."]},{"key":"dc:creator","label":"Author","values":["DiLorenzo, Daniel John"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-08-22T20:22:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-08-22T20:22:07Z"]},{"key":"dc:date.issued","label":"Date","values":["1999"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Harvard University--MIT Division of Health Sciences and Technology."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/9329"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Harvard--Massachusetts Institute of Technology Division of Health Sciences and Technology, 1999.","Includes bibliographical references (leaves 42-44)."]},{"key":"dc:description.abstract","label":"Abstract","values":["The functionality of prosthetic limbs is restricted by the limited availability of sensory feedback. This research aims to develop a technology to allow the presentation of sensory information directly to the sensory afferent neurons of the transected peripheral nerve in the stump of the amputee. lntraneural implants of several designs were developed and implanted in rabbit animal models and monitored for chronic functionality evaluated using both neurophysiological and behavioral tests. Animal studies have demonstrated single channel implant functionality of up to 129 days. The relative merit of the designs is assessed, and future directions for implant design and behavioral testing are suggested."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of a chronically implanted microelectrode array for intraneural electrical stimulation for prosthetic sensory feedback"]}]}],"canonical_facts":{"dc:contributor.advisor":["David J. Edell."],"dc:contributor.department":["Harvard University--MIT Division of Health Sciences and Technology."],"dc:contributor.other":["Harvard University--MIT Division of Health Sciences and Technology."],"dc:creator":["DiLorenzo, Daniel John"],"dc:date.accessioned":["2005-08-22T20:22:07Z"],"dc:date.available":["2005-08-22T20:22:07Z"],"dc:date.issued":["1999"],"dc:description":["Thesis (S.M.)--Harvard--Massachusetts Institute of Technology Division of Health Sciences and Technology, 1999.","Includes bibliographical references (leaves 42-44)."],"dc:description.abstract":["The functionality of prosthetic limbs is restricted by the limited availability of sensory feedback. This research aims to develop a technology to allow the presentation of sensory information directly to the sensory afferent neurons of the transected peripheral nerve in the stump of the amputee. lntraneural implants of several designs were developed and implanted in rabbit animal models and monitored for chronic functionality evaluated using both neurophysiological and behavioral tests. Animal studies have demonstrated single channel implant functionality of up to 129 days. The relative merit of the designs is assessed, and future directions for implant design and behavioral testing are suggested."],"dc:description.degree":["S.M."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/9329"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Harvard University--MIT Division of Health Sciences and Technology."],"dc:title":["Development of a chronically implanted microelectrode array for intraneural electrical stimulation for prosthetic sensory feedback"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:02Z"}