Back to results

Massachusetts Institute of Technology

Design and implementation of a fiber optic doppler optical coherence microscopy system for cochlear imaging

Abstract

dc:description.abstract

In this thesis, the design and implementation of a fiber optic Doppler optical coherence microscopy (FO-DOCM) system for cochlear imaging applications is presented. The use of a fiber optic design significantly reduces system size and complexity and the construction of a novel alignment and micropositioning apparatus increases ease of use for the researcher performing the imaging. To enable precise measurements of tissue motion, a time domain DOCM approach is used, utilizing an acousto-optic modulator (AOM) based optical heterodyne system to generate a stationary interference carrier frequency. By referencing this interference signal against the AOM drive signals, measurements of motions with magnitude on the order of 10 pm are shown to be possible. In addition to interferometrically measuring small amplitude motion, the FO-DOCM system is shown to be capable of imaging with a volumetric resolution of 10 x 9 x 9 pm. Demonstrative results of imaging cochlear tissue are presented by using the FO-DOCM system to image and measure motion in a guinea pig cochlea in vitro.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Williams, Logan P
Advisor dc:contributor.advisor
  • Dennis M. Freeman.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/92090
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/92090

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Williams, Logan P. Design and implementation of a fiber optic doppler optical coherence microscopy system for cochlear imaging. Massachusetts Institute of Technology, 2014. http://hdl.handle.net/1721.1/92090