Back to results

Massachusetts Institute of Technology

Reducing booster-pump-induced contaminant intrusion in Indian water systems with a self-actuated, back-pressure regulating valve

Abstract

dc:description.abstract

Intermittently-operated water systems struggle to equitably and effectively distribute clean water to customers. One common customer response to intermittency is to supplement the water system's pressure by using a household, or residential, booster pump. When such booster pumps are directly connected to the water utility's supply pipe, without an underground isolation tank (sump), they often induce negative pressure in the supply pipe which increases the flow rate. Unfortunately, where leakage rates are high, this negative pressure also increases the risk of contaminant intrusion. This thesis presents the iterative design and field testing of a patent-pending, full-bore, back-pressure regulating valve. The valve's simple mechanism relies on a stabilized collapsing tube, or 'Starling Resistor,'which when installed at a customer's connection, controls the flow rate and prevents booster pumps from creating negative pressure in the supply pipe. In collaboration with the Delhi Jal Board and several private partners, the valve's performance was verified in two rounds of field trials in neighborhoods of New Delhi, India including Pitampura, Azad Market, Vivek Vihar, Malvia Nagar, and Vasant Vihar. Using a crossover study, the valve was found to reduce the total contamination risk across all 19 tested houses during supply times by a median of 80%. The valve prevented 96% of pressure below -1 meter and an average of 53 minutes per day, per connection of total negative pressure. In an estimated worst-case scenario for contaminant intrusion, the presence of the valve reduced the contamination risk by two orders of magnitude at six customer connections - enough to correspond to significant reductions in health risks.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Taylor, David Donald James
Advisor dc:contributor.advisor
  • Alexander H. Slocum.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/92062
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/92062

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Taylor, David Donald James. Reducing booster-pump-induced contaminant intrusion in Indian water systems with a self-actuated, back-pressure regulating valve. Massachusetts Institute of Technology, 2014. http://hdl.handle.net/1721.1/92062