Back to results

Massachusetts Institute of Technology

Single-site, noninvasive, blood pressure measurements at the ear using ballistocardiogram (BCG), and photoplethysmogram (PPG), and a low-power, reflectance-mode PPG SoC

Abstract

dc:description.abstract

This work presents a wearable congestive heart failure (CHF) monitor at the ear that uses the ballistocardiogram (BCG), electrocardiogram (ECG), and photoplethysmogram (PPG) to extract mean blood pressure up the Carotid Artery. Being a natural anchoring point, the ear is demonstrated as a viable location for the integrated sensing of physiological signals. The BCG is obtained with an accelerometer, the ECG is taken in a single lead configuration, with one electrode at the mastoid and one on the back of the neck, and the PPG is measured by reflecting light off of the mastoid region above Reid's baseline. When the BCG and PPG are used together, a time delay of the blood pulse wave can be obtained, known as the pulse transit time (PTT), from a single site of measurement. The ear-worn device is wirelessly connected to a computer for real-time data recording. A clinical test involving hemodynamic maneuvers is performed on 15 subjects. The results demonstrate a linear relationship between mean blood pressure and ln(1/PTT ). Using amplitude information from the BCG signal allows for improving the accuracy of the PTT-to-BP algorithm without additional sensors. While the clinical device uses commercial components, a custom integrated circuit for reflectance-mode PPG is designed with the goal of removing static and time-varying interferers while minimizing power consumption and device size. The chip nominally consumes 425[mu]W and only requires LEDs and photodiodes to operate, replacing 7 chips and a MATLAB program compared to the discrete version. The circuit architecture leverages analog and digital techniques to remove up to 100[mu]A of static interferers and attenuate time-varying interferers by 87dB.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Winokur, Eric S., 1984-
Advisor dc:contributor.advisor
  • Charles G. Sodini.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/91038
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/91038

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Winokur, Eric S., 1984-. Single-site, noninvasive, blood pressure measurements at the ear using ballistocardiogram (BCG), and photoplethysmogram (PPG), and a low-power, reflectance-mode PPG SoC. Massachusetts Institute of Technology, 2014. http://hdl.handle.net/1721.1/91038