Back to results

Massachusetts Institute of Technology

Requirements for the detection of atherosclerosis lesions in carotid arteries with SPECT

Abstract

dc:description.abstract

Detecting the metabolic state of atherosclerotic lesions is a promise of nuclear medicine imaging. Several researchers are developing radiopharmaceuticals for atherosclerosis imaging. In this thesis, we provided procedural guidelines to detect carotid lesions with single photon ,Emission Computed Tomography (SPECT). We first established a method to assess the requirements for "successful" lesion detection. Although this method was used to detect focal carotid lesions, it is also applicable to the detection of focal lesions in other arteries or veins. We measured lesion detectability using the output values of a 3D moving Non Pre-Whitening Matched Filter (30 mNPWMF) with the .Localization Receiver Operating Characteristics (LROC) paradigm. We simulated SPECT images of the neck using SimSPECT, our in-house analog Monte Carlo radiation transport code. We used 400 64x64 reconstructed images formed by 99mTc photons of a focal lesion in a carotid artery next to a jugular vein, both in a cylindrical water neck. We then applied the 3D \ mNPWMF along the large neck vessels. The NPWMF has been found to correlate well with human observers in simple ROC studies. We expect the mNPWMF operation to mimic a radiologist who already has a blood pool image which identifies the location of the large neck vessels. Using this detection method, we calculated that 1 to 6 kBq/cm were needed in the lesion. At large blood activity (4.6 times the surrounding tissue activity), the minimum radiopharmaceutical uptake increased by 1.6-2.9 times when the patient was lying down as opposed to sitting up. At this blood activity, a carotid dilation of 1 cm radius distracted the moving Matched Filter from lesion detection. We recommend that the blood activity be as low as possible to avoid any focal dilation from distracting our detector. We recommend that, at high blood activity, the patient be imaged in an upright position in which the jugular veins are collapsed, preventing their blood pool activity from obscuring the carotid arteries. Finally, we showed that a lesion needed 140% of the radiopharmaceutical when acquired with a radius of rotation (ROR) of25 cm instead of 15 cm. In conclusion, we assessed successfully the effect of the jugular veins and carotid dilation on detection of carotid lesions in SPECT images of the neck using the LROC detection paradigm.

Degree

thesis:*
Department dc:contributor.department
Harvard University--MIT Division of Health Sciences and Technology.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bélanger, Marie-José, 1967-
Advisor dc:contributor.advisor
  • Jacquelyn C. Yanch.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/9028
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/9028

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Bélanger, Marie-José, 1967-. Requirements for the detection of atherosclerosis lesions in carotid arteries with SPECT. Massachusetts Institute of Technology, 2000. http://hdl.handle.net/1721.1/9028