{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/89966"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/89966","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Swelling properties of hydrogel coatings on neural devices","abstract":"Glial scarring is a major problem seen in brain electrode implants that can hinder electrode function. One major contributing factor is the mechanical mismatch between the stiff electrode and the soft brain tissue'. Hydrogel coatings are being investigated to determine their effectiveness in providing the necessary biocompatibility. Polyethylene glycol hydrogels of various formulations were fabricated and produced elastic moduli ranging from 13kPa to 687 kPa, which lie within two orders of magnitude of the elastic moduli of the brain (6kPa). Dehydration of the hydrogels provides the mechanical rigidity necessary for implantation into the brain. The surrounding aqueous environment allows the dried hydrogel to return to its swollen state. The swelling process in the brain phantom is slower than in unconstrained swelling. The equilibrium swollen hydrogel was also slightly smaller in the constrained state, implying the strain is being distributed between the hydrogel and the brain phantom.","abstract_html":"Glial scarring is a major problem seen in brain electrode implants that can hinder electrode function. One major contributing factor is the mechanical mismatch between the stiff electrode and the soft brain tissue&#x27;. Hydrogel coatings are being investigated to determine their effectiveness in providing the necessary biocompatibility. Polyethylene glycol hydrogels of various formulations were fabricated and produced elastic moduli ranging from 13kPa to 687 kPa, which lie within two orders of magnitude of the elastic moduli of the brain (6kPa). Dehydration of the hydrogels provides the mechanical rigidity necessary for implantation into the brain. The surrounding aqueous environment allows the dried hydrogel to return to its swollen state. The swelling process in the brain phantom is slower than in unconstrained swelling. The equilibrium swollen hydrogel was also slightly smaller in the constrained state, implying the strain is being distributed between the hydrogel and the brain phantom.","abstract_has_math":false,"creators":["Deng, Di Judy"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Materials Science and Engineering.","school":null,"contributors":[],"advisors":["Michael J. Cima."],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-07-22T22:21:14Z","subjects":["Materials Science and Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/89966","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Michael J. Cima."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Materials Science and Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Materials Science and Engineering."]},{"key":"dc:creator","label":"Author","values":["Deng, Di Judy"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-09-19T21:31:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-09-19T21:31:37Z"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Materials Science and Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/89966"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis: S.B., Massachusetts Institute of Technology, Department of Materials Science and Engineering, 2014.","Cataloged from PDF version of thesis.","Includes bibliographical references (page 30)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Glial scarring is a major problem seen in brain electrode implants that can hinder electrode function. One major contributing factor is the mechanical mismatch between the stiff electrode and the soft brain tissue'. Hydrogel coatings are being investigated to determine their effectiveness in providing the necessary biocompatibility. Polyethylene glycol hydrogels of various formulations were fabricated and produced elastic moduli ranging from 13kPa to 687 kPa, which lie within two orders of magnitude of the elastic moduli of the brain (6kPa). Dehydration of the hydrogels provides the mechanical rigidity necessary for implantation into the brain. The surrounding aqueous environment allows the dried hydrogel to return to its swollen state. The swelling process in the brain phantom is slower than in unconstrained swelling. The equilibrium swollen hydrogel was also slightly smaller in the constrained state, implying the strain is being distributed between the hydrogel and the brain phantom."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Swelling properties of hydrogel coatings on neural devices"]}]}],"canonical_facts":{"dc:contributor.advisor":["Michael J. Cima."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Materials Science and Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Materials Science and Engineering."],"dc:creator":["Deng, Di Judy"],"dc:date.accessioned":["2014-09-19T21:31:37Z"],"dc:date.available":["2014-09-19T21:31:37Z"],"dc:date.issued":["2014"],"dc:description":["Thesis: S.B., Massachusetts Institute of Technology, Department of Materials Science and Engineering, 2014.","Cataloged from PDF version of thesis.","Includes bibliographical references (page 30)."],"dc:description.abstract":["Glial scarring is a major problem seen in brain electrode implants that can hinder electrode function. One major contributing factor is the mechanical mismatch between the stiff electrode and the soft brain tissue'. Hydrogel coatings are being investigated to determine their effectiveness in providing the necessary biocompatibility. Polyethylene glycol hydrogels of various formulations were fabricated and produced elastic moduli ranging from 13kPa to 687 kPa, which lie within two orders of magnitude of the elastic moduli of the brain (6kPa). Dehydration of the hydrogels provides the mechanical rigidity necessary for implantation into the brain. The surrounding aqueous environment allows the dried hydrogel to return to its swollen state. The swelling process in the brain phantom is slower than in unconstrained swelling. The equilibrium swollen hydrogel was also slightly smaller in the constrained state, implying the strain is being distributed between the hydrogel and the brain phantom."],"dc:description.degree":["S.B."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/89966"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Materials Science and Engineering."],"dc:title":["Swelling properties of hydrogel coatings on neural devices"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:14Z"}