Back to results

Massachusetts Institute of Technology

Ultrasound stimulated acoustic emission for monitoring thermal surgery

Abstract

dc:description.abstract

Therapeutic ultrasound describes a non-invasive surgical technique by which high-energy ultrasound is delivered to malignant tissue. This method must be monitored in order to ensure that the correct tissues are treated and that the tissues are treated with the proper dose. Typically, therapeutic ultrasound has relied on MRI techniques to monitor the extent of the thermal surgery. Besides for the great cost and limited availability, MRI monitoring presents limitations for therapeutic equipment design because all other equipment must be compatible with the large magnetic fields created by the MRI system. A new method of monitoring is explored which uses a method coined Ultrasound Stimulated Acoustic Emission, USAE. This relatively new material property measurement method presented by M. Fatemi and J.F. Greenleaf in Science May 1998 relies on the low frequency stimulation of a material by overlapping two slightly differing high frequency ultrasound beams in a pattern which creates a region of low frequency, known as a beat frequency. The resulting low frequency stimulus is highly focused and localized. The low frequency pressure field causes cyclic forces and induces a mechanical displacement in the object being imaged. The low frequency response of the object from the ultrasound stimulus reveals information about the mechanical and ultrasound properties of the object, namely its stiffness and acoustical absorption coefficient. A diagnostic ultrasound system applying the USAE method for imaging biological tissues was designed and constructed for use in this thesis. In a series of experiments presented in this thesis, the USAE method is applied to imaging ex vivo porcine and rabbit tissue. Lesions are created with focused ultrasound and raster scanned in the focal plane by the two intersecting focused ultrasound fields to image the necrosed tissue. This method successfully rendered high-resolution images of the necrosed lesions. In addition, the amplitude of the USAE responses correlate well with temperature measurements in a study of nine samples of porcine fat and nine samples of porcine muscle. Evidence including a broadband response and fluctuating USAE amplitude indicate that the USAE method may also be used to detect cavitation events in tissue. The images and the temperature measurements demonstrate the effectiveness of the USAE method for imaging and monitoring biological tissue in conjunction with thermal therapy.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Thierman, Jonathan S. (Jonathan Sidney), 1976-
Advisor dc:contributor.advisor
  • Kullervo Hynynen and Ernest G. Cravalho.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/8880
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/8880

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Thierman, Jonathan S. (Jonathan Sidney), 1976-. Ultrasound stimulated acoustic emission for monitoring thermal surgery. Massachusetts Institute of Technology, 2001. http://hdl.handle.net/1721.1/8880