A need exists for small, robust, and efficient cryocoolers operating in the 25-100 K range; however, while technological advances have enabled the development of such machines, a greater understanding of the losses affecting their performance is needed to make informed design tradeoffs. This thesis takes steps to provide this understanding by examining several losses in the context of a multi-stage cryocooler being developed by MIT and Advanced Mechanical Technologies, Inc. Based on a modular Collins-type design, this cryocooler will use computer-controlled floating piston expanders to simultaneously provide 20 and 100 Watts of cooling at 25 and 100 K, respectively. The contributions in this thesis can be divided into two broad categories. The first is concerned with the systems-level efficiency of the cryocooler, and addresses a significant inefficiency caused by an inherent cooler-to-load temperature mismatch. By using an alternative cryocooler configuration with multiple expanders in series, the overall efficiency may be increased by an estimated 24%. A simple memorizable heuristic was also found to estimate the magnitude of the mismatch loss in a given stage of the cryocooler: the fractional increase in operating power is approximately the base-10 logarithm of the pressure ratio divided by twice the number of series expanders, assuming a monatomic working fluid. The second area of research focused on the design of the cryocooler's unique floating piston expanders. A variety of losses affect the performance of these expanders; these range from the obvious to the obscure (e.g., the enhanced "shuttle" heat transfer that arises from reciprocating piston motion) and often favor conflicting design choices. Eleven such losses are discussed along with both existing literature and a new analysis of fluid flow and heat transfer in the piston-cylinder gap. A numerical model incorporating six of these losses was used to gain considerable insight into the design tradeoffs involved in expander design and provide preliminary support for the multi-expander designs discussed earlier. The simulations also challenged a previous design guideline for the piston's stroke length and, unexpectedly, revealed that imperfect expansion and compression can yield a net increase in expander efficiency due to the importance of shuttle heat transfer.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Segado, Martin Alan
Advisor dc:contributor.advisor
  • John G. Brisson II.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/87793
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/87793

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Segado, Martin Alan. Analysis and mitigation of key losses in a multi-stage 25-100 K cryocooler. Massachusetts Institute of Technology, 2014. http://hdl.handle.net/1721.1/87793