Back to results

Massachusetts Institute of Technology

Design of a biomechanically synergistic exotendon suit

Abstract

dc:description.abstract

The focus of this thesis is on the design, development, and evaluation of a lightweight, exotendon suit for load carriage. The suit is intended to be worn underneath the wearer's own clothes for use in a military setting, while reducing the energy expenditure of the wearer. A simple exotendon suit architecture was designed and implemented, consisting of two knee braces, a length of polypropylene tendon, a belt, two electro-magnet clutches, and a control box. The electro-magnet clutches are mounted at the waist and tendons are used to apply the actuator's force to the wearer's ankles. This is advantageous, as many current exoskeletons mount actuators at the ankles, requiring a greater amount of additional energy expenditure. Testing was performed at the Wyss Institute for Biologically Inspired Engineering Motion Capture Laboratory. Metabolic power was tested using a COSMED K4b2 system and surface electromyogram (sEMG) data was collected using a Delsys Trigno system. Five male subjects participated in six trials, walking on a treadmill at 1.25 m/s, carrying a 20 kg load in a standard military rucksack. The six trials consisted of three conditions: street clothes, exosuit worn but unpowered (passive), and exosuit word and powered (active). Results of the tests were inconclusive. There was no significant evidence that powering the exosuit has a positive or negative effect on the wearer's energy usage.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Graves, Carmen Marten-Ellis
Advisor dc:contributor.advisor
  • Sangbae Kim.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/85497
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/85497

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Graves, Carmen Marten-Ellis. Design of a biomechanically synergistic exotendon suit. Massachusetts Institute of Technology, 2013. http://hdl.handle.net/1721.1/85497