Back to results

Massachusetts Institute of Technology

An investigation into the design of an image reconstruction algorithm for continuous wave tomosynthesis

Abstract

dc:description.abstract

Continuous wave (CW) tomosynthesis provides many theoretical advantages over traditional breast imaging techniques, like mammography. These theoretical advantages include improved spatial resolution, better information weighting, and the ability to resolve structures hidden by tissue overlap. However, unlike mammography, tomosynthesis is a three-dimensional imaging modality and it will require a complex reconstruction algorithm to process its projection data and recreate the object planes. This paper details a reconstruction algorithm proposed for continuous wave tomosynthesis which is based on the filtered back-projection reconstruction algorithm used in computed tomography. The algorithm for tomosynthesis requires modifications to the filtered back-projection algorithm in order to account for the lack of complete data which is generated by a tomosynthesis scan. In order to demonstrate the potential viability of a CW tomosynthesis reconstruction algorithm, the modified reconstruction algorithm is applied to several simulated phantom images and analyzed for reconstructed image quality.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Douyon, Pierre-Guy Felix
Advisor dc:contributor.advisor
  • Cardinal Warde and Louis Poulo.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/85415
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/85415

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Douyon, Pierre-Guy Felix. An investigation into the design of an image reconstruction algorithm for continuous wave tomosynthesis. Massachusetts Institute of Technology, 2013. http://hdl.handle.net/1721.1/85415