Thermal properties of granular silica aerogel for high-performance insulation systems

Abstract

dc:description.abstract

Based on mounting evidence in support of anthropogenic global climate change, there is an urgency for developments in high-performance building techniques and technologies. New construction projects provide substantial opportunities for energy efficiency measures, but they represent only a small portion of the building stock. Conversely, while existing buildings are plentiful, they typically have a much narrower range of feasible energy efficiency options. Therefore, there will continue to be a need for the development of new and improved energy efficiency measures for new building construction and even more so for deep retrofits of existing buildings. This thesis provides an overview of the research performed into the on-going development at MIT of a high-performance panelized insulation system based on silica aerogel. Two test methods were used for measuring the thermal conductivity of the granules: the transient hot-wire technique and the guarded hot-plate system. Utilizing the hot-wire set-up, it was demonstrated that compressing a bed of granules will decrease the thermal conductivity of the system until a minimum point is reached around the monolithic density of the aerogel. For the Cabot granules, this was seen at 13 mW/m-K and about 150 kg/m3. The MIT granules showed equal performance to the Cabot granules at bed densities 20-30 kg/m3 lower. The hot-plate testing was able to experimentally evaluate previous analytical predictions regarding the conductivity impact of the internal panel truss and the under-prediction of radiant heat transfer in the hot-wire method. Hot-wire testing was also done in a vacuum chamber to quantify potential performance improvements at reduced air pressures. Since a vacuum would require the incorporation of a barrier film into the panel system, some analyses were done into the thermal bridging potential and gas diffusion requirements of such a film. Additionally, physical prototyping was done to explore how the film would be incorporated into the existing panel design. The aerogel-based insulation panel being developed at MIT continues to show promise, though there are still plenty of opportunities remaining in the development cycle.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Architecture.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Neugebauer, Adam (Adam Halbert)
Advisor dc:contributor.advisor
  • Leon Glicksman.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/85213
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/85213

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Neugebauer, Adam (Adam Halbert). Thermal properties of granular silica aerogel for high-performance insulation systems. Massachusetts Institute of Technology, 2013. http://hdl.handle.net/1721.1/85213