{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/83818"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/83818","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Measurement of sin² 2[theta]₁₃ using delayed neutron capture on hydrogen in Double CHOOZ","abstract":"Double CHOOZ is a reactor antineutrino experiment built to measure [theta]13. The experiment is designed to use two detectors at different baselines (400 m and 1 km) to precisely measure the disappearance of ve from the Chooz reactor cores in Ardenne, France. Our inverse beta decay (IBD) signal is a two-fold coincidence of a prompt positron followed by a delayed neutron capture on gadolinium. The delayed neutron capture releases 8 MeV of energy from multiple gamma rays and is easily distinguished from natural radioactive backgrounds. While delayed neutron capture on gadolinium is used in all the reactor-based [theta]13 measurements [1, 2, 3], it is also possible to detect IBD via delayed neutron capture on hydrogen. In Double CHOOZ the Hydrogen detection channel has twice the signal statistics as the gadolinium detection channel, and provides an independent data sample with which to cross-check the gadolinium analysis result. The first result [4] is found to be sin² 2[theta]₁₃ = 0.097 ± 0.034 (stat) ± 0.034 (syst). The author lead the collaboration to make this measurement possible, and the detail of the work is presented in this document.","abstract_html":"Double CHOOZ is a reactor antineutrino experiment built to measure [theta]13. The experiment is designed to use two detectors at different baselines (400 m and 1 km) to precisely measure the disappearance of ve from the Chooz reactor cores in Ardenne, France. Our inverse beta decay (IBD) signal is a two-fold coincidence of a prompt positron followed by a delayed neutron capture on gadolinium. The delayed neutron capture releases 8 MeV of energy from multiple gamma rays and is easily distinguished from natural radioactive backgrounds. While delayed neutron capture on gadolinium is used in all the reactor-based [theta]13 measurements [1, 2, 3], it is also possible to detect IBD via delayed neutron capture on hydrogen. In Double CHOOZ the Hydrogen detection channel has twice the signal statistics as the gadolinium detection channel, and provides an independent data sample with which to cross-check the gadolinium analysis result. The first result [4] is found to be sin² 2[theta]₁₃ = 0.097 ± 0.034 (stat) ± 0.034 (syst). The author lead the collaboration to make this measurement possible, and the detail of the work is presented in this document.","abstract_has_math":false,"creators":["Terao, Kazuhiro"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Physics.","school":null,"contributors":[],"advisors":["Janet M. Conrad."],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-07-22T22:22:24Z","subjects":["Physics."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/83818","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Janet M. Conrad."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Physics."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Physics."]},{"key":"dc:creator","label":"Author","values":["Terao, Kazuhiro"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-01-09T19:58:24Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-01-09T19:58:24Z"]},{"key":"dc:date.issued","label":"Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/83818"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Physics, 2013.","In title on title-page, \"[theta]\" appears as the lower-case Greek letter. Cataloged from PDF version of thesis.","Includes bibliographical references (pages 199-204)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Double CHOOZ is a reactor antineutrino experiment built to measure [theta]13. The experiment is designed to use two detectors at different baselines (400 m and 1 km) to precisely measure the disappearance of ve from the Chooz reactor cores in Ardenne, France. Our inverse beta decay (IBD) signal is a two-fold coincidence of a prompt positron followed by a delayed neutron capture on gadolinium. The delayed neutron capture releases 8 MeV of energy from multiple gamma rays and is easily distinguished from natural radioactive backgrounds. While delayed neutron capture on gadolinium is used in all the reactor-based [theta]13 measurements [1, 2, 3], it is also possible to detect IBD via delayed neutron capture on hydrogen. In Double CHOOZ the Hydrogen detection channel has twice the signal statistics as the gadolinium detection channel, and provides an independent data sample with which to cross-check the gadolinium analysis result. The first result [4] is found to be sin² 2[theta]₁₃ = 0.097 ± 0.034 (stat) ± 0.034 (syst). The author lead the collaboration to make this measurement possible, and the detail of the work is presented in this document."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:title","label":"Title","values":["Measurement of sin² 2[theta]₁₃ using delayed neutron capture on hydrogen in Double CHOOZ"]}]}],"canonical_facts":{"dc:contributor.advisor":["Janet M. Conrad."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Physics."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Physics."],"dc:creator":["Terao, Kazuhiro"],"dc:date.accessioned":["2014-01-09T19:58:24Z"],"dc:date.available":["2014-01-09T19:58:24Z"],"dc:date.issued":["2013"],"dc:description":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Physics, 2013.","In title on title-page, \"[theta]\" appears as the lower-case Greek letter. Cataloged from PDF version of thesis.","Includes bibliographical references (pages 199-204)."],"dc:description.abstract":["Double CHOOZ is a reactor antineutrino experiment built to measure [theta]13. The experiment is designed to use two detectors at different baselines (400 m and 1 km) to precisely measure the disappearance of ve from the Chooz reactor cores in Ardenne, France. Our inverse beta decay (IBD) signal is a two-fold coincidence of a prompt positron followed by a delayed neutron capture on gadolinium. The delayed neutron capture releases 8 MeV of energy from multiple gamma rays and is easily distinguished from natural radioactive backgrounds. While delayed neutron capture on gadolinium is used in all the reactor-based [theta]13 measurements [1, 2, 3], it is also possible to detect IBD via delayed neutron capture on hydrogen. In Double CHOOZ the Hydrogen detection channel has twice the signal statistics as the gadolinium detection channel, and provides an independent data sample with which to cross-check the gadolinium analysis result. The first result [4] is found to be sin² 2[theta]₁₃ = 0.097 ± 0.034 (stat) ± 0.034 (syst). The author lead the collaboration to make this measurement possible, and the detail of the work is presented in this document."],"dc:description.degree":["Ph.D."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/83818"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Physics."],"dc:title":["Measurement of sin² 2[theta]₁₃ using delayed neutron capture on hydrogen in Double CHOOZ"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:24Z"}