Back to results

Massachusetts Institute of Technology

Two-Color interferometry as a fluctuation diagnostic on Alcator C-Mod

Abstract

dc:description.abstract

The two-color interferometer diagnostic on Alcator C-Mod has been upgraded to measure line-integrated electron density fluctuations for turbulence and transport studies. Heterodyne signals from ten vertical-viewing CO2 laser chords are demodulated relative to a local oscillator using high bandwidth analog in-phase/quadrature electronics, replacing lower bandwidth digital fringe counting electronics. The raw outputs of the high bandwidth electronics, which are proportional to the sine and cosine of the interferometric phase shift, are digitized at up to 10 MHz, which is sufficient for fluctuation analysis. Extraction of the measured phase from the sine and cosine signals is now performed entirely in software, providing the line-integrated electron density at high bandwidth. The interferometer design, calibration, and measurement uncertainty is presented. Measurement uncertainties due to nonlinearities in the analog electronics are found to be comparable to the uncertainties of the previous system. The interferometer can now resolve line-integrated electron density fluctuations with major-radial wavenumbers below ... . The new fluctuation measurement capability is used to partially verify the calibration and low-kR wavenumber response of phase-contrast imaging, to aid in gyrokinetic transport model validation research. Agreement between the two diagnostics is demonstrated for broadband fluctuations and the low-kR component of the quasi-coherent mode, improving confidence in the calibration of the phase-contrast imaging system. Both diagnostics observe a series of fluctuations during quasi-steady periods of minority heated I-mode plasmas with strong off-axis electron heating. The observed fluctuations are localized to the plasma core using Doppler shift analysis and data from edge fluctuation diagnostics. Transport analysis shows that the fluctuations do not correlate with enhanced thermal transport, and gyrokinetic linear stability analysis shows that the plasma is stable to drift wave turbulence, ruling out the possibility that the observed fluctuations are destabilized drift wave turbulence.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kasten, Cale Phillip
Advisor dc:contributor.advisor
  • Anne E. White.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/82457
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/82457

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Kasten, Cale Phillip. Two-Color interferometry as a fluctuation diagnostic on Alcator C-Mod. Massachusetts Institute of Technology, 2013. http://hdl.handle.net/1721.1/82457