Back to results

Massachusetts Institute of Technology

Analysis and characterization of ancillary service demand response strategies for variable air volume HVAC systems

Abstract

dc:description.abstract

Output variability and prediction difficulties with respect to solar and wind electricity resources increase the requirement of grid-scale reserve capacity and add strain to existing firm generators used for reserves and other ancillary services. Residential and commercial buildings account for a large portion of the electricity consumed in the U.S. and can play a significant role in smart grids to help meet challenges brought about by intermittent renewable generation. High resolution power consumption and HVAC performance data measured in a real building was used to identify real-world operational qualities of VAV systems to be considered by building researchers and building practitioners. This includes the relative magnitude of building power loads, the direct and indirect relationships between environmental conditions and HVAC power consumption, the discrete operation of staged or cycled power loads, and the presence of HVAC operational faults. Also, three static pressure adjustment tests were performed over a one day period. Results showed that fan and terminal unit controllers responded within two minutes and system air flowrate was strongly related to power consumption. Dynamic models were created in order to simulate the performance of a VAV system providing spinning reserves by four different common demand response strategies: zone air dry bulb temperature setpoint adjustment (ZDBA), duct static pressure setpoint adjustment (SPA), supply air temperature adjustment (STA), and chilled water temperature adjustment (CWA). Simulations were run over ranges of implementation and cooling load intensities and the results were used to create characteristic curves for each strategy, which map performance in terms of system power consumption reduction, system airflow reduction, and zone temperature rise. Inflection points on the curves that delineate performance effectiveness are found to result from maximum or minimum terminal unit damper positions. In the future, the development of mathematical functional forms of these characterization curves could help predict and optimize the performance of VAV systems in providing ancillary services to electricity networks.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Architecture.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Blum, David H. (David Henry)
Advisor dc:contributor.advisor
  • Leslie K. Norford.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/82162
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/82162

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Blum, David H. (David Henry). Analysis and characterization of ancillary service demand response strategies for variable air volume HVAC systems. Massachusetts Institute of Technology, 2013. http://hdl.handle.net/1721.1/82162