Back to results

Massachusetts Institute of Technology

Thermal design of a cooled micro gas turbine

Abstract

dc:description.abstract

One of the major challenges associated with designing a micro gas turbine engine is the problem of heat transfer. The demonstration version of the engine deals with this problem by transferring excess heat from the turbine, to the compressor wall, through the rotor shaft. This is necessary to keep the turbine wall within its temperature constraints. The resulting heat transfer into the compressor flow however reduces the compressor performance to the point that the cycle will no longer close. A film cooled turbine has thus been pursued as a means of keeping the turbine within its temperature constraints and at the same time reducing heat transfer to the compressor. The thermal design of this cooled micro gas turbine has involved the design of the thermodynamic cycle, a secondary flow system to carry compressor discharge air to the turbine for cooling, and conceptual design of a turbine and rotor shaft to match the compressor. The analysis leading to this design identified turbine wall temperature, turbine exit radius and shaft area as three tools for increasing the power of the turbine, required to close the cycle. The design converged upon revealed that a very high cooling effectiveness is required to close the cycle, if the turbine wall is to be limited to 950K. This high effectiveness is calculated according to an empirical model established with data from full size engines, and thus represents an extrapolation of data with its attendant risks. A comparative model was developed as a regression of CFD results produced for the engine geometry. This model predicts adiabatic cooling effectiveness values too low to close the cycle. From the cycles studied, the recommended cycle configuration includes a 10mm diameter turbine with 1600K at rotor inlet. 41% of compressor inlet air is required to cool the turbine wall to 950K, and shaft area required to be 0.1% of a solid 6mm diameter shaft, i.e. 0.079mm2. The resulting cycle breaks even with a compressor pressure ratio of 2.46 and efficiency of 43%. Turbine efficiency is 63%. This solution shows that closure of the cycle is possible. It however suggests that further design study and technology development is needed to generate useful levels of engine performance.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Evans, Simon William, 1977-
Advisor dc:contributor.advisor
  • Alan H. Epstein.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/8093
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/8093

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Evans, Simon William, 1977-. Thermal design of a cooled micro gas turbine. Massachusetts Institute of Technology, 2001. http://hdl.handle.net/1721.1/8093