Abstract
dc:description.abstractMRI magnets are useful medical devices in early detection and efficient treatment of disease or injury. Because of the significant better performance, MRI magnets are made of superconductors rather than made of copper. Nowadays, there are over 20,000 superconducting MRI magnets installed worldwide. Most of them are made of NbTi or Nb₃Sn, but they are usually very expensive to purchase or operate. So, my colleagues chose MgB₂ wires to develop low-cost and easy-to-operate MRI units which serve to the majority of the humanity. Because we have a reliable technology to fabricate superconducting joints with monofilament MgB₂ wire, we decided to build our MgB₂ MRI magnet with monofilament wire instead of multifilament wire. Previously, flux jumping was found to be the main issue with monofilament superconducting wire; we have to demonstrate that flux jumping is not a big issue with monofilament MgB₂ wire before we can build our MRI magnet with it. In this thesis, a series of experiments was designed and carried out to prove that the monofilament MgB₂ wire performs as well as the multifilament MgB₂ wire in MRI magnet applications. Short samples of monofilament MgB₂ wires were tested, and magnetization trace of the short samples showed that flux jumping could be a minor issue with monofilament MgB₂ wire. Three 100-m sample coils made of multifilament MgB₂ wire, monofilament MgB₂ wire, and monofilament NbTi wire were wound, tested and compared. The results of these tests demonstrated that the monofilament MgB₂ wire has insignificant flux jumping which does not lead to a premature quench. So, monofilament MgB₂ wire is potentially a good option for MRI magnets.
Degree
thesis:*- Department dc:contributor.department
- Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
- Grantor dc:publisher
- Massachusetts Institute of Technology
- Year dc:date.issued
- 2012
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ling, Jiayin
- Advisor dc:contributor.advisor
-
- Yukikazu Iwasa.
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
- Licence dc:rights.uri
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- http://hdl.handle.net/1721.1/78185
- OAI identifier oai:identifier
- oai:dspace.mit.edu:1721.1/78185