Patient positioning is crucial to accurate dose delivery during radiation therapy to ensure the proper localization of dose to the target tumor volume. In patient positioning for stereotactic radiation therapy treatment, classical image registration methods are computationally costly and imprecise. We developed an automatic, fast, and robust 2D-3D registration method to improve accuracy and speed of identifying 6 degrees-of-freedom (DoF) transformations during patient positioning for stereotactic radiotherapy by creating a model of characteristic shape distributions to determine the linear relationship between two real-time orthogonal 2D projection images and the 3D volume image. We defined a preprocessed sparse base set of shape distributions that characterize 2D digitally reconstructed radiograph (DRR) images from a range of independent transformations of the volume. The algorithm calculates the 6-DoF transformation of the patient based upon two orthogonal real-time 2D images by correlating the images against the base set The algorithm has positioning accuracy to at least 1 pixel, equivalent to 0.5098 mm accuracy given this image resolution. The shape distribution of each 2D image is created in MATLAB in an average of 0.017 s. The online algorithm allows for rapid and accurate position matching of the images, providing the transformation needed to align the patient on average in 0.5276 s. The shape distribution algorithm affords speed, robustness, and accuracy of patient positioning during stereotactic radiotherapy treatment for small-order 6-DoF transformations as compared with existing techniques for the quantification of patient setup where both linear and rotational deviations occur. This algorithm also indicates the potential for rapid, high precision patient positioning from the interpolation and extrapolation of the linear relationships based upon shape distributions. Key words: shape distribution, image registration, patient positioning, radiation therapy

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lin, Christie
Advisor dc:contributor.advisor
  • Richard C. Lanza and Brian Winey.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/76969
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/76969

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Lin, Christie. Linear regression analysis of 2D projection image data of 6 degrees-of-freedom transformed 3D image sets for stereotactic radiation therapy. Massachusetts Institute of Technology, 2012. http://hdl.handle.net/1721.1/76969