{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/76904"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/76904","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Biomaterials for protection and repair of the central nervous system","abstract":"An injectable hydrogel for controlled release of methylprednisolone was designed based on the inflammatory response during acute spinal cord injury. The gel is injectable through a small gauge needle, cross-links under physiological conditions, and releases methylprednisolone over a time period on the order of weeks. Swelling properties were characterized to address potential safety concerns for potential clinical use. Two studies are presented towards the development of a model Brown-Sequard syndrome and accompanying behavioral and pathological outcome measures for evaluation of biomaterials in vivo. A modified poly(glycerol-co-sebacic acid) membrane was developed using electrospun poly(s-caprolactone) nanofibers. Retinal adhesion and histology was evaluated in vitro. Membranes were evaluated in vivo for their ability to selectively remove photoreceptors in situ and promote survival and integration of retinal transplants. Viscoelastic poly(ethylene glycol) sols were evaluated as potential vitreous substitutes. Finally, a business plan outlines the strategy towards clinical trials for a hydrogel vitreous substitute.","abstract_html":"An injectable hydrogel for controlled release of methylprednisolone was designed based on the inflammatory response during acute spinal cord injury. The gel is injectable through a small gauge needle, cross-links under physiological conditions, and releases methylprednisolone over a time period on the order of weeks. Swelling properties were characterized to address potential safety concerns for potential clinical use. Two studies are presented towards the development of a model Brown-Sequard syndrome and accompanying behavioral and pathological outcome measures for evaluation of biomaterials in vivo. A modified poly(glycerol-co-sebacic acid) membrane was developed using electrospun poly(s-caprolactone) nanofibers. Retinal adhesion and histology was evaluated in vitro. Membranes were evaluated in vivo for their ability to selectively remove photoreceptors in situ and promote survival and integration of retinal transplants. Viscoelastic poly(ethylene glycol) sols were evaluated as potential vitreous substitutes. Finally, a business plan outlines the strategy towards clinical trials for a hydrogel vitreous substitute.","abstract_has_math":false,"creators":["Pritchard, Christopher D., (Christopher David)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Chemical Engineering.","school":null,"contributors":[],"advisors":["Robert Langer."],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-07-22T22:20:58Z","subjects":["Chemical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/76904","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Robert Langer."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Chemical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Chemical Engineering."]},{"key":"dc:creator","label":"Author","values":["Pritchard, Christopher D., (Christopher David)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-02-14T15:15:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-02-14T15:15:51Z"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/76904"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Chemical Engineering, 2012.","\"June 2012.\" Cataloged from PDF version of thesis.","Includes bibliographical references."]},{"key":"dc:description.abstract","label":"Abstract","values":["An injectable hydrogel for controlled release of methylprednisolone was designed based on the inflammatory response during acute spinal cord injury. The gel is injectable through a small gauge needle, cross-links under physiological conditions, and releases methylprednisolone over a time period on the order of weeks. Swelling properties were characterized to address potential safety concerns for potential clinical use. Two studies are presented towards the development of a model Brown-Sequard syndrome and accompanying behavioral and pathological outcome measures for evaluation of biomaterials in vivo. A modified poly(glycerol-co-sebacic acid) membrane was developed using electrospun poly(s-caprolactone) nanofibers. Retinal adhesion and histology was evaluated in vitro. Membranes were evaluated in vivo for their ability to selectively remove photoreceptors in situ and promote survival and integration of retinal transplants. Viscoelastic poly(ethylene glycol) sols were evaluated as potential vitreous substitutes. Finally, a business plan outlines the strategy towards clinical trials for a hydrogel vitreous substitute."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:title","label":"Title","values":["Biomaterials for protection and repair of the central nervous system"]}]}],"canonical_facts":{"dc:contributor.advisor":["Robert Langer."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Chemical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Chemical Engineering."],"dc:creator":["Pritchard, Christopher D., (Christopher David)"],"dc:date.accessioned":["2013-02-14T15:15:51Z"],"dc:date.available":["2013-02-14T15:15:51Z"],"dc:date.issued":["2012"],"dc:description":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Chemical Engineering, 2012.","\"June 2012.\" Cataloged from PDF version of thesis.","Includes bibliographical references."],"dc:description.abstract":["An injectable hydrogel for controlled release of methylprednisolone was designed based on the inflammatory response during acute spinal cord injury. The gel is injectable through a small gauge needle, cross-links under physiological conditions, and releases methylprednisolone over a time period on the order of weeks. Swelling properties were characterized to address potential safety concerns for potential clinical use. Two studies are presented towards the development of a model Brown-Sequard syndrome and accompanying behavioral and pathological outcome measures for evaluation of biomaterials in vivo. A modified poly(glycerol-co-sebacic acid) membrane was developed using electrospun poly(s-caprolactone) nanofibers. Retinal adhesion and histology was evaluated in vitro. Membranes were evaluated in vivo for their ability to selectively remove photoreceptors in situ and promote survival and integration of retinal transplants. Viscoelastic poly(ethylene glycol) sols were evaluated as potential vitreous substitutes. Finally, a business plan outlines the strategy towards clinical trials for a hydrogel vitreous substitute."],"dc:description.degree":["Ph.D."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/76904"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Chemical Engineering."],"dc:title":["Biomaterials for protection and repair of the central nervous system"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:20:58Z"}