{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/76141"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/76141","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Design and optimization of a humidifier for an HDH system","abstract":"Two billion people around the world do not access to clean drinking water. 98% of deaths caused by water related illness occur in the developing world. The humidification dehumidification desalination system currently being developed at the Lienhard Research Laboratory is a water treatment technology with low operational requirements that make it ideal for operation in the developing world. Researchers in the lab have just developed a novel design methodology for optimizing the performance of an HDH system based on thermal balancing, similar to the methodology used in heat exchanger design. An experimental pilot sized unit was built to test this methodology on a packed bed humidifier. Non-dimensional entropy generation was shown to have a minimum value for varied mass flow ratio as well as for varied water inlet temperature. At its optimal performance condition, the humidifier built for this thesis has a temperature pinch of 2.8 °C and an enthalpy pinch of 14.8 kJ/kg dry air. For the first time in literature, this thesis has experimentally shown that the balanced condition of HCR=1 corresponds to the condition of minimum entropy generation, validating the design methodology previously proposed at the Lienhard Lab.","abstract_html":"Two billion people around the world do not access to clean drinking water. 98% of deaths caused by water related illness occur in the developing world. The humidification dehumidification desalination system currently being developed at the Lienhard Research Laboratory is a water treatment technology with low operational requirements that make it ideal for operation in the developing world. Researchers in the lab have just developed a novel design methodology for optimizing the performance of an HDH system based on thermal balancing, similar to the methodology used in heat exchanger design. An experimental pilot sized unit was built to test this methodology on a packed bed humidifier. Non-dimensional entropy generation was shown to have a minimum value for varied mass flow ratio as well as for varied water inlet temperature. At its optimal performance condition, the humidifier built for this thesis has a temperature pinch of 2.8 °C and an enthalpy pinch of 14.8 kJ/kg dry air. For the first time in literature, this thesis has experimentally shown that the balanced condition of HCR=1 corresponds to the condition of minimum entropy generation, validating the design methodology previously proposed at the Lienhard Lab.","abstract_has_math":false,"creators":["St. John, Maximus Gladstone"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["John H. Lienhard V."],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-07-22T22:22:05Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/76141","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["John H. Lienhard V."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["St. John, Maximus Gladstone"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-07T21:24:16Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-07T21:24:16Z"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/76141"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 55-56)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Two billion people around the world do not access to clean drinking water. 98% of deaths caused by water related illness occur in the developing world. The humidification dehumidification desalination system currently being developed at the Lienhard Research Laboratory is a water treatment technology with low operational requirements that make it ideal for operation in the developing world. Researchers in the lab have just developed a novel design methodology for optimizing the performance of an HDH system based on thermal balancing, similar to the methodology used in heat exchanger design. An experimental pilot sized unit was built to test this methodology on a packed bed humidifier. Non-dimensional entropy generation was shown to have a minimum value for varied mass flow ratio as well as for varied water inlet temperature. At its optimal performance condition, the humidifier built for this thesis has a temperature pinch of 2.8 °C and an enthalpy pinch of 14.8 kJ/kg dry air. For the first time in literature, this thesis has experimentally shown that the balanced condition of HCR=1 corresponds to the condition of minimum entropy generation, validating the design methodology previously proposed at the Lienhard Lab."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Design and optimization of a humidifier for an HDH system"]}]}],"canonical_facts":{"dc:contributor.advisor":["John H. Lienhard V."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["St. John, Maximus Gladstone"],"dc:date.accessioned":["2013-01-07T21:24:16Z"],"dc:date.available":["2013-01-07T21:24:16Z"],"dc:date.issued":["2012"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 55-56)."],"dc:description.abstract":["Two billion people around the world do not access to clean drinking water. 98% of deaths caused by water related illness occur in the developing world. The humidification dehumidification desalination system currently being developed at the Lienhard Research Laboratory is a water treatment technology with low operational requirements that make it ideal for operation in the developing world. Researchers in the lab have just developed a novel design methodology for optimizing the performance of an HDH system based on thermal balancing, similar to the methodology used in heat exchanger design. An experimental pilot sized unit was built to test this methodology on a packed bed humidifier. Non-dimensional entropy generation was shown to have a minimum value for varied mass flow ratio as well as for varied water inlet temperature. At its optimal performance condition, the humidifier built for this thesis has a temperature pinch of 2.8 °C and an enthalpy pinch of 14.8 kJ/kg dry air. For the first time in literature, this thesis has experimentally shown that the balanced condition of HCR=1 corresponds to the condition of minimum entropy generation, validating the design methodology previously proposed at the Lienhard Lab."],"dc:description.degree":["S.B."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/76141"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Design and optimization of a humidifier for an HDH system"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:05Z"}