{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/75639"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/75639","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Energy storage for frequency regulation on the electric grid","abstract":"Ancillary services such as frequency regulation are required for reliable operation of the electric grid. Currently, the same traditional thermal generators that supply bulk power also perform nearly all frequency regulation. Instead, using high power energy storage resources to provide frequency regulation can allow traditional thermal generators to operate more smoothly. However, using energy storage alone for frequency regulation would require an unreasonably large energy storage capacity. Duration curves for energy capacity and instantaneous ramp rate are used to evaluate the requirements and benefits of using energy storage for a component of frequency regulation. Filtering is used to separate the portion of a frequency regulation control signal suitable for provision by an energy storage unit from the portion suitable for provision by traditional thermal generating resources. Not all frequency regulation signals are equally amenable to the filtering approach used here. Data from two U.S. control areas are used to demonstrate the techniques and the results are compared.","abstract_html":"Ancillary services such as frequency regulation are required for reliable operation of the electric grid. Currently, the same traditional thermal generators that supply bulk power also perform nearly all frequency regulation. Instead, using high power energy storage resources to provide frequency regulation can allow traditional thermal generators to operate more smoothly. However, using energy storage alone for frequency regulation would require an unreasonably large energy storage capacity. Duration curves for energy capacity and instantaneous ramp rate are used to evaluate the requirements and benefits of using energy storage for a component of frequency regulation. Filtering is used to separate the portion of a frequency regulation control signal suitable for provision by an energy storage unit from the portion suitable for provision by traditional thermal generating resources. Not all frequency regulation signals are equally amenable to the filtering approach used here. Data from two U.S. control areas are used to demonstrate the techniques and the results are compared.","abstract_has_math":false,"creators":["Leitermann, Olivia"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.","school":null,"contributors":[],"advisors":["James L. Kirtley, Jr."],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-07-22T22:21:09Z","subjects":["Electrical Engineering and Computer Science."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/75639","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["James L. Kirtley, Jr."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Leitermann, Olivia"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-12-13T18:48:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-12-13T18:48:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/75639"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2012.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 271-280)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Ancillary services such as frequency regulation are required for reliable operation of the electric grid. Currently, the same traditional thermal generators that supply bulk power also perform nearly all frequency regulation. Instead, using high power energy storage resources to provide frequency regulation can allow traditional thermal generators to operate more smoothly. However, using energy storage alone for frequency regulation would require an unreasonably large energy storage capacity. Duration curves for energy capacity and instantaneous ramp rate are used to evaluate the requirements and benefits of using energy storage for a component of frequency regulation. Filtering is used to separate the portion of a frequency regulation control signal suitable for provision by an energy storage unit from the portion suitable for provision by traditional thermal generating resources. Not all frequency regulation signals are equally amenable to the filtering approach used here. Data from two U.S. control areas are used to demonstrate the techniques and the results are compared."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:title","label":"Title","values":["Energy storage for frequency regulation on the electric grid"]}]}],"canonical_facts":{"dc:contributor.advisor":["James L. Kirtley, Jr."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:creator":["Leitermann, Olivia"],"dc:date.accessioned":["2012-12-13T18:48:18Z"],"dc:date.available":["2012-12-13T18:48:18Z"],"dc:date.issued":["2012"],"dc:description":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2012.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 271-280)."],"dc:description.abstract":["Ancillary services such as frequency regulation are required for reliable operation of the electric grid. Currently, the same traditional thermal generators that supply bulk power also perform nearly all frequency regulation. Instead, using high power energy storage resources to provide frequency regulation can allow traditional thermal generators to operate more smoothly. However, using energy storage alone for frequency regulation would require an unreasonably large energy storage capacity. Duration curves for energy capacity and instantaneous ramp rate are used to evaluate the requirements and benefits of using energy storage for a component of frequency regulation. Filtering is used to separate the portion of a frequency regulation control signal suitable for provision by an energy storage unit from the portion suitable for provision by traditional thermal generating resources. Not all frequency regulation signals are equally amenable to the filtering approach used here. Data from two U.S. control areas are used to demonstrate the techniques and the results are compared."],"dc:description.degree":["Ph.D."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/75639"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Energy storage for frequency regulation on the electric grid"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:09Z"}