{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/74986"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/74986","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Skin strain analysis software for the study of human skin deformation","abstract":"Skin strain studies have never been conducted in a precise and automated fashion. Previous in vivo strain investigations have been labor intensive and the data resolution was extremely limited such that their results were largely qualitative. There is a need for a better system to collect, compute, and output strain measurements of the skin in vivo for the purpose of designing better mechanical interfaces with the body. Interfaces that have the same strain behavior as human skin can minimize shear forces and discomfort for the user. One particular application is improving the design of prosthetic liners for amputees, creating a second skin sleeve that provides support without hindering movement. A custom approach offering high resolution marker density, automatic point tracking and correspondences, and computational transparency is presented in this thesis. The entire computational toolbox is presented, which takes in high resolution digital photographs, tracks points on the surface of the body, corresponds points between body poses, computes a series of strain measures, and graphically displays these data. The results of studies of a full bodied human knee and a transtibial amputee's residual limb are presented here as well.","abstract_html":"Skin strain studies have never been conducted in a precise and automated fashion. Previous in vivo strain investigations have been labor intensive and the data resolution was extremely limited such that their results were largely qualitative. There is a need for a better system to collect, compute, and output strain measurements of the skin in vivo for the purpose of designing better mechanical interfaces with the body. Interfaces that have the same strain behavior as human skin can minimize shear forces and discomfort for the user. One particular application is improving the design of prosthetic liners for amputees, creating a second skin sleeve that provides support without hindering movement. A custom approach offering high resolution marker density, automatic point tracking and correspondences, and computational transparency is presented in this thesis. The entire computational toolbox is presented, which takes in high resolution digital photographs, tracks points on the surface of the body, corresponds points between body poses, computes a series of strain measures, and graphically displays these data. The results of studies of a full bodied human knee and a transtibial amputee&#x27;s residual limb are presented here as well.","abstract_has_math":false,"creators":["Marecki, Andrew T. (Andrew Thomas)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Hugh M. Herr."],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-07-22T22:21:24Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/74986","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hugh M. Herr."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Marecki, Andrew T. (Andrew Thomas)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-19T19:32:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-19T19:32:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/74986"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 58)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Skin strain studies have never been conducted in a precise and automated fashion. Previous in vivo strain investigations have been labor intensive and the data resolution was extremely limited such that their results were largely qualitative. There is a need for a better system to collect, compute, and output strain measurements of the skin in vivo for the purpose of designing better mechanical interfaces with the body. Interfaces that have the same strain behavior as human skin can minimize shear forces and discomfort for the user. One particular application is improving the design of prosthetic liners for amputees, creating a second skin sleeve that provides support without hindering movement. A custom approach offering high resolution marker density, automatic point tracking and correspondences, and computational transparency is presented in this thesis. The entire computational toolbox is presented, which takes in high resolution digital photographs, tracks points on the surface of the body, corresponds points between body poses, computes a series of strain measures, and graphically displays these data. The results of studies of a full bodied human knee and a transtibial amputee's residual limb are presented here as well."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:title","label":"Title","values":["Skin strain analysis software for the study of human skin deformation"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hugh M. Herr."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Marecki, Andrew T. (Andrew Thomas)"],"dc:date.accessioned":["2012-11-19T19:32:29Z"],"dc:date.available":["2012-11-19T19:32:29Z"],"dc:date.issued":["2012"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 58)."],"dc:description.abstract":["Skin strain studies have never been conducted in a precise and automated fashion. Previous in vivo strain investigations have been labor intensive and the data resolution was extremely limited such that their results were largely qualitative. There is a need for a better system to collect, compute, and output strain measurements of the skin in vivo for the purpose of designing better mechanical interfaces with the body. Interfaces that have the same strain behavior as human skin can minimize shear forces and discomfort for the user. One particular application is improving the design of prosthetic liners for amputees, creating a second skin sleeve that provides support without hindering movement. A custom approach offering high resolution marker density, automatic point tracking and correspondences, and computational transparency is presented in this thesis. The entire computational toolbox is presented, which takes in high resolution digital photographs, tracks points on the surface of the body, corresponds points between body poses, computes a series of strain measures, and graphically displays these data. The results of studies of a full bodied human knee and a transtibial amputee's residual limb are presented here as well."],"dc:description.degree":["S.M."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/74986"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Skin strain analysis software for the study of human skin deformation"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:24Z"}