{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/74944"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/74944","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Design of a low-cost autoclave for adoption in rural health posts of the developing world","abstract":"Incidence of surgical site infection is two to five times higher in developing nations as compared to developed nations. Autoclaves kill all dangerous pathogens, including heat-resistant endospores, and are an essential tool to achieving and maintaining a sterile environment, which decreases risk of infection. A low-cost, easy to use autoclave was designed to address the unique technical, behavioral, and market challenges present in rural health posts of the developing world. A thorough stakeholder analysis was performed very early in the design process to address needs for sustained user adoption as well as manufacturability and scalability. Twelve partnering clinics in Nepal trialed these autoclaves from July until December 2012. Usage statistics from this period and follow-up observations highlight important factors for successful adoption. These findings were used to improve the autoclave design in a second iteration.","abstract_html":"Incidence of surgical site infection is two to five times higher in developing nations as compared to developed nations. Autoclaves kill all dangerous pathogens, including heat-resistant endospores, and are an essential tool to achieving and maintaining a sterile environment, which decreases risk of infection. A low-cost, easy to use autoclave was designed to address the unique technical, behavioral, and market challenges present in rural health posts of the developing world. A thorough stakeholder analysis was performed very early in the design process to address needs for sustained user adoption as well as manufacturability and scalability. Twelve partnering clinics in Nepal trialed these autoclaves from July until December 2012. Usage statistics from this period and follow-up observations highlight important factors for successful adoption. These findings were used to improve the autoclave design in a second iteration.","abstract_has_math":false,"creators":["Tao, Gregory Daniel"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Daniel Frey and Amos Winter."],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-07-22T22:20:47Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/74944","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Daniel Frey and Amos Winter."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Tao, Gregory Daniel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-19T19:20:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-19T19:20:37Z"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/74944"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 69-71)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Incidence of surgical site infection is two to five times higher in developing nations as compared to developed nations. Autoclaves kill all dangerous pathogens, including heat-resistant endospores, and are an essential tool to achieving and maintaining a sterile environment, which decreases risk of infection. A low-cost, easy to use autoclave was designed to address the unique technical, behavioral, and market challenges present in rural health posts of the developing world. A thorough stakeholder analysis was performed very early in the design process to address needs for sustained user adoption as well as manufacturability and scalability. Twelve partnering clinics in Nepal trialed these autoclaves from July until December 2012. Usage statistics from this period and follow-up observations highlight important factors for successful adoption. These findings were used to improve the autoclave design in a second iteration."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:title","label":"Title","values":["Design of a low-cost autoclave for adoption in rural health posts of the developing world"]}]}],"canonical_facts":{"dc:contributor.advisor":["Daniel Frey and Amos Winter."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Tao, Gregory Daniel"],"dc:date.accessioned":["2012-11-19T19:20:37Z"],"dc:date.available":["2012-11-19T19:20:37Z"],"dc:date.issued":["2012"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 69-71)."],"dc:description.abstract":["Incidence of surgical site infection is two to five times higher in developing nations as compared to developed nations. Autoclaves kill all dangerous pathogens, including heat-resistant endospores, and are an essential tool to achieving and maintaining a sterile environment, which decreases risk of infection. A low-cost, easy to use autoclave was designed to address the unique technical, behavioral, and market challenges present in rural health posts of the developing world. A thorough stakeholder analysis was performed very early in the design process to address needs for sustained user adoption as well as manufacturability and scalability. Twelve partnering clinics in Nepal trialed these autoclaves from July until December 2012. Usage statistics from this period and follow-up observations highlight important factors for successful adoption. These findings were used to improve the autoclave design in a second iteration."],"dc:description.degree":["S.M."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/74944"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Design of a low-cost autoclave for adoption in rural health posts of the developing world"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:20:47Z"}