Modeling water use at thermoelectric power plants

Abstract

dc:description.abstract

The withdrawal and consumption of water at thermoelectric power plants affects regional ecology and supply security of both water and electricity. The existing field data on US power plant water use, however, is of limited granularity and poor quality, hampering efforts to track industry trends and project future scenarios. Furthermore, there is a need for a common quantitative framework on which to evaluate the effects of various technologies on water use at power plants. To address these deficiencies, Part 1 of this thesis develops an analytical system-level generic model (SGEM) of water use at power plants. The S-GEM applies to fossil, nuclear, geothermal and solar thermal plants, using either steam or combined cycles, and outputs water withdrawal and consumption intensity, in liters per megawatt-hour. Two validations of the S-GEM are presented, one against data from the literature for a variety of generation types, the other against field data from coal plants in South Africa. Part 2 of the thesis then focuses on cooling systems, by far the largest consumers of water in most power plants. The water consumption of different cooling systems is placed on a common quantitative basis, enabling direct comparison of water consumption between cooling system types, and examination of the factors that affect water consumption within each cooling system type. The various cost, performance, and environmental impact tradeoffs associated with once-through, pond, wet tower, dry, and hybrid cooling technologies are qualitatively reviewed. Part 3 examines cooling of concentrating solar power (CSP) plants, which presents particular problems: the plants generate high waste heat loads, are usually located in water-scarce areas, and are typically on the margin of economic viability. A case study is conducted to explore the use of indirect dry cooling with cold-side thermal energy storage, in which cooling water is chilled and stored at night, when ambient temperatures are lower and the plant is inactive, and then used the following day. This approach is shown to hold promise for reducing the capital, operational, and performance costs of dry cooling for CSP.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rutberg, Michael J. (Michael Jacob)
Advisor dc:contributor.advisor
  • Ahmed F. Ghoniem.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/74674
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/74674

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Rutberg, Michael J. (Michael Jacob). Modeling water use at thermoelectric power plants. Massachusetts Institute of Technology, 2012. http://hdl.handle.net/1721.1/74674