Back to results

Massachusetts Institute of Technology

Analysis of headless shear stud connections

Abstract

dc:description.abstract

Highway bridges are exposed to numerous elemental and loading issues that are extremely difficult for a designer to anticipate and account for during design. The current state of practice is to design a bridge deck for a certain life span and then turn the bridge over to maintenance personnel who attempt to prolong the life of the deck through a variety of repair and rehabilitation measures. These repair measures are rarely, if ever, considered during the design process of the bridge deck. Numerous researchers have looked at making bridges, specifically decks, more repairable. The majority of these research efforts have focused on the bridge deck system as a whole. Other researchers have looked at individual elements of the bridge deck to girder connection to see if the required strength could be achieved while making the connections easier to take apart. One of the main components in the bridge deck to girder system is the steel shear stud connection, which is used to create composite action between the deck and the girder. Numerous researchers have studied this connection from a strength perspective, and the strength equations for the shear connection have been codified. Shear connections using headless studs have been researched as well, but always as a part of a larger deck to girder connection system. The headless stud has never been researched to see how it responds to a shear loading. This study looks at headless studs with varying levels of debonding along the stud shaft to analyze the impact on the load resistance that the levels of debonding would have. Granular materials for the shear transfer of load are also looked at. The results show that, as expected, the headless, debonded shear studs can carry less load than a bonded stud, but the difference in load carrying capacity is within the suggested over-estimation range of the codes that other researchers have suggested. These results suggest that the use of headless, debonded shear studs in a deck to girder connection is a feasible way to make that connection more repairable.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Civil and Environmental Engineering
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Spittka, Berndt F. (Berndt Friedrich), 1980-
Advisor dc:contributor.advisor
  • Jerome J. Connor.

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/74404
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/74404

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Spittka, Berndt F. (Berndt Friedrich), 1980-. Analysis of headless shear stud connections. Massachusetts Institute of Technology, 2012. http://hdl.handle.net/1721.1/74404