Back to results

Massachusetts Institute of Technology

Development of a concentration-enhanced mobility shift assay platform for aptamer-based biomarker detection and kinase profiling

Abstract

dc:description.abstract

New methods to quantify rare biomarkers from patient samples are critical for developing point-of- care diagnostic platforms. To be compatible with resource limited settings, these assays have to provide fast and accurate results without sacrificing ease of use. Biosensing in homogeneous fashion is the preferred format which satisfies these criteria, but the lack of amplification method is a bottleneck that limits their use for sensitive applications. To address this issue, this thesis explores physical signal amplification means to increase the sensitivities of homogeneous assays. We identified several key applications where the use of these technologies could make a positive impact in improving medical diagnostics systems and advancing biological research. We first outline the use of electrokinetic concentration to realize a continuous signal amplification scheme that increases the sensitivity of homogeneous mobility shift assays. By simultaneously concentrating and separating reacted and unreacted species (with different mobilities) in this device, we can perform sensitive, quantitative and ratiometric measurement of target biomarkers. Using this platform, we improved the sensitivity of aptamer affinity probe capillary electrophoresis to achieve pM detection limit of IgE and HIV-RT in simple buffer and serum sample. This work is timely and impactful as it directly addresses the sensitivity shortcomings of using aptamers as low cost and robust substitutes for antibodies in point-of-care applications. Next, we presented a herringbone nanofilter array device which can perform continuous sizes-elective concentration of biomolecules based on their direct interaction with nanostructures with comparable critical dimensions. We demonstrated the use of this platform to perform a novel homogeneous immunoassay for detecting a cardiac biomarker, C-reactive protein, at clinically relevant concentrations. Finally, we demonstrated that the concentration-enhanced mobility shift assay platform is a powerful tool for probing biological activities such as cellular kinase activities. We have developed technology to isolate, grow and lyse single cells, and used our platform to measure kinase activities from single cells. Through rational design of peptide substrates and spacers, this platform has the ability to simultaneously concentrate and separate multiple analytes. This enables users to obtain simultaneous measurements of multiple cellular kinase activities that could reveal important information about their functional relationships.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Cheow, Lih Feng
Advisor dc:contributor.advisor
  • Jongyoon Han.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/71513
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/71513

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Cheow, Lih Feng. Development of a concentration-enhanced mobility shift assay platform for aptamer-based biomarker detection and kinase profiling. Massachusetts Institute of Technology, 2012. http://hdl.handle.net/1721.1/71513