Back to results

Massachusetts Institute of Technology

Heat pipe dehumidification for supermarket energy savings

Abstract

dc:description.abstract

This thesis examines the possibility of using a heat pipe installed in the air conditioning unit of a supermarket to increase the level of dehumidification of the inside air. This dehumidification is expected to reduce the energy consumption of the refrigeration system due to an improved efficiency of the heat transfer at the display case. This increase in efficiency will be due to reduced frost buildup on the refrigeration coils. Chapter two includes a physical and psychometric analysis of the heat pipe, proving that for any system where direct evaporation dehumidification is used, at any given time when dehumidification is being performed, the addition of a heat pipe will increase the amount of moisture being removed by the cooling coil. For this thesis, a heat pipe was installed in a supermarket in Worcester, Massachusetts. Over a period of the summer from the beginning of June to the end of October, various air temperatures and relative humidities, refrigeration line temperatures, pressures, and mass flows, and compressor power consumption were monitored for fifteen minute periods. The monitoring period included two months before the installation and three months after the installation to determine changes in the air system and refrigeration system due to the presence of the heat pipe. Chapters two through five describe the equipment, site and strategy used in the analysis. Chapter six describes the results of the monitoring, and Chapters seven and eight give the results of the air system and refrigeration system models. The systems were modelled using monitored data and engineering equations to predict humidity levels and power consumption based on ambient conditions. The analysis was unique in that a heat pipe application had never been previously studied in a Northeast location, since the mild summers made dehumidification less of an issue than in Southern states. This study was also considerably more in depth than previous studies (summarized in Chapter 2), for which savings estimates do not account for large potential errors. This study concluded that potential savings estimates (0-8% reduction in supply air humidity, -1 % reduction in refrigeration power) were within statistical error (9% for specific humidity, 4% for refrigeration power), and therefore inconclusive. Further studies with superior equipment and modelling strategies are needed to substantiate heat pipe dehumidification.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Architecture.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
1994

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Oliver, Eric M. (Eric Michael)
Advisor dc:contributor.advisor
  • Leslie K. Norford.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/69327
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/69327

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Oliver, Eric M. (Eric Michael). Heat pipe dehumidification for supermarket energy savings. Massachusetts Institute of Technology, 1994. http://hdl.handle.net/1721.1/69327