{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/69211"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/69211","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Electricity meterings as an integral part of an energy conservation program","abstract":"Energy management has always been an issue for facility managers, but is now coming under increased scrutiny as businesses become more concerned with greenhouse gas emissions and their environmental footprint. Contemporary research suggests that simply feeding back information on energy use can result in a reduction of consumption between 5 and 20%. The building block of this feedback loop is the energy meter, which is typically standard equipment in homes, but not always installed in commercial buildings, particularly large corporate campuses. Since energy meters have been treated as an added cost in the past, they are not as widely deployed as energy managers would like. However, an analysis of electricity rate structures and hourly electricity use patterns can help identify which buildings provide the shortest payback period for electric meter installation. Raytheon Missile Systems in Tucson, Arizona was able to identify five buildings with a simple payback of under one year, 19 buildings with a positive NPV over two years, and 48 buildings with a positive NPV over 10 years for electric meter installations. Energy meters also provide immediate feedback on usage, verification of utility bills, and the ability to understand peak demand. As a part of an energy conservation program, energy meters are often overlooked, but are a critical building block for data gathering, monitoring, and feedback.","abstract_html":"Energy management has always been an issue for facility managers, but is now coming under increased scrutiny as businesses become more concerned with greenhouse gas emissions and their environmental footprint. Contemporary research suggests that simply feeding back information on energy use can result in a reduction of consumption between 5 and 20%. The building block of this feedback loop is the energy meter, which is typically standard equipment in homes, but not always installed in commercial buildings, particularly large corporate campuses. Since energy meters have been treated as an added cost in the past, they are not as widely deployed as energy managers would like. However, an analysis of electricity rate structures and hourly electricity use patterns can help identify which buildings provide the shortest payback period for electric meter installation. Raytheon Missile Systems in Tucson, Arizona was able to identify five buildings with a simple payback of under one year, 19 buildings with a positive NPV over two years, and 48 buildings with a positive NPV over 10 years for electric meter installations. Energy meters also provide immediate feedback on usage, verification of utility bills, and the ability to understand peak demand. As a part of an energy conservation program, energy meters are often overlooked, but are a critical building block for data gathering, monitoring, and feedback.","abstract_has_math":false,"creators":["Follette, David J. (David Junichi)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Leaders for Global Operations Program at MIT","school":null,"contributors":[],"advisors":["David E. Hardt and Sarah Slaughter."],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-07-22T22:22:22Z","subjects":["Mechanical Engineering.","Sloan School of Management.","Leaders for Global Operations Program."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/69211","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["David E. Hardt and Sarah Slaughter."]},{"key":"dc:contributor.department","label":"Department","values":["Leaders for Global Operations Program at MIT","Massachusetts Institute of Technology. Department of Mechanical Engineering","Sloan School of Management"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Leaders for Global Operations Program."]},{"key":"dc:creator","label":"Author","values":["Follette, David J. (David Junichi)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-02-24T20:52:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-02-24T20:52:46Z"]},{"key":"dc:date.issued","label":"Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering.","Sloan School of Management.","Leaders for Global Operations Program."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/69211"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering; and, (M.B.A.)--Massachusetts Institute of Technology, Sloan School of Management; in conjunction with the Leaders for Global Operations Program at MIT, 2010.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 77-79)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Energy management has always been an issue for facility managers, but is now coming under increased scrutiny as businesses become more concerned with greenhouse gas emissions and their environmental footprint. Contemporary research suggests that simply feeding back information on energy use can result in a reduction of consumption between 5 and 20%. The building block of this feedback loop is the energy meter, which is typically standard equipment in homes, but not always installed in commercial buildings, particularly large corporate campuses. Since energy meters have been treated as an added cost in the past, they are not as widely deployed as energy managers would like. However, an analysis of electricity rate structures and hourly electricity use patterns can help identify which buildings provide the shortest payback period for electric meter installation. Raytheon Missile Systems in Tucson, Arizona was able to identify five buildings with a simple payback of under one year, 19 buildings with a positive NPV over two years, and 48 buildings with a positive NPV over 10 years for electric meter installations. Energy meters also provide immediate feedback on usage, verification of utility bills, and the ability to understand peak demand. As a part of an energy conservation program, energy meters are often overlooked, but are a critical building block for data gathering, monitoring, and feedback."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.B.A.","S.M."]},{"key":"dc:title","label":"Title","values":["Electricity meterings as an integral part of an energy conservation program"]}]}],"canonical_facts":{"dc:contributor.advisor":["David E. Hardt and Sarah Slaughter."],"dc:contributor.department":["Leaders for Global Operations Program at MIT","Massachusetts Institute of Technology. Department of Mechanical Engineering","Sloan School of Management"],"dc:contributor.other":["Leaders for Global Operations Program."],"dc:creator":["Follette, David J. (David Junichi)"],"dc:date.accessioned":["2012-02-24T20:52:46Z"],"dc:date.available":["2012-02-24T20:52:46Z"],"dc:date.issued":["2010"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering; and, (M.B.A.)--Massachusetts Institute of Technology, Sloan School of Management; in conjunction with the Leaders for Global Operations Program at MIT, 2010.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 77-79)."],"dc:description.abstract":["Energy management has always been an issue for facility managers, but is now coming under increased scrutiny as businesses become more concerned with greenhouse gas emissions and their environmental footprint. Contemporary research suggests that simply feeding back information on energy use can result in a reduction of consumption between 5 and 20%. The building block of this feedback loop is the energy meter, which is typically standard equipment in homes, but not always installed in commercial buildings, particularly large corporate campuses. Since energy meters have been treated as an added cost in the past, they are not as widely deployed as energy managers would like. However, an analysis of electricity rate structures and hourly electricity use patterns can help identify which buildings provide the shortest payback period for electric meter installation. Raytheon Missile Systems in Tucson, Arizona was able to identify five buildings with a simple payback of under one year, 19 buildings with a positive NPV over two years, and 48 buildings with a positive NPV over 10 years for electric meter installations. Energy meters also provide immediate feedback on usage, verification of utility bills, and the ability to understand peak demand. As a part of an energy conservation program, energy meters are often overlooked, but are a critical building block for data gathering, monitoring, and feedback."],"dc:description.degree":["M.B.A.","S.M."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/69211"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering.","Sloan School of Management.","Leaders for Global Operations Program."],"dc:title":["Electricity meterings as an integral part of an energy conservation program"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:22Z"}