Back to results

Massachusetts Institute of Technology

The Soralux Daylighting System : passive solar illumination for deep-plan building spaces

Abstract

dc:description.abstract

Daylight is a valuable resource for both energy and human health. However, this resource is often underutilized in buildings due to the difficulty of controlling the changing qualities of daylight. Deep-plan building spaces pose an especially challenging problem because traditional sidelighting strategies are only effective for workplanes adjacent to the facade. Infrequently adjusted shading systems can also limit the availability of daylight. A number of advanced daylighting systems have been developed that attempt to address these challenges with varying priorities and success. This thesis proposes a new technology named the Soralux Daylighting System. The system is passive, requires no shading adjustments, even under direct sunlight, and works well with deep-plan spaces on the order of 8 to 15 m deep. The Soralux system presents itself as a double-glazing window unit, allowing it to be easily integrated into curtain wall facades typical of deep-plan offices in large cities. Computer simulations using the ray tracing programs Radiance and TracePro were conducted to estimate the annual performance of the system. Variables such as facade orientation, sky obstruction, and climate were evaluated for their effect on system performance. The system was found to increase light levels by a factor of 2 to 10 compared to an unshaded window at depths between 8 and 15 m from the facade. Two physical mockups of the Soralux system were fabricated for testing. The first mockup tested was a small proof-of-concept prototype, while the second was a full-scale mockup which was installed in a Tokyo office building. The physical mockups were used to evaluate visual comfort and appearance. A monitoring campaign was also conducted for the Tokyo mockup and the measured data were compared with a Radiance model of the building space to validate the accuracy of the simulation results. The average error between simulated and measured illuminance values was 16%. Based on these results, recommendations are provided identifying which scenarios are well-suited for the system. The Soralux Daylighting System is scheduled to be permanently installed into a Tokyo office building in 2012.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Thuot, Kevin W. (Kevin William)
Advisor dc:contributor.advisor
  • Marilyne Andersen and Leon Glicksman.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/67824
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/67824

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Thuot, Kevin W. (Kevin William). The Soralux Daylighting System : passive solar illumination for deep-plan building spaces. Massachusetts Institute of Technology, 2011. http://hdl.handle.net/1721.1/67824