{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/67584"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/67584","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Development and performance of a miniature, low cost mass spectrometer","abstract":"A miniature, low cost mass spectrometer has been developed that is capable of unit resolution over a mass range of 10 to 50 AMU. The design of the mass spectrometer incorporates several new features that enhance the performance of the design over comparable instruments. An efficient ion source allows a relatively low power consumption without sacrificing resolution. Variable geometry mechanical filters allow for variable resolution. An onboard ion pump removes the need for an external pumping source. An onboard digital controller allows a large degree of flexibility over the operation of the mass spectrometer while eliminating the need for high voltage electrical feedthroughs. The miniature mass spectrometer is sensitive to fractions of a percentage of inlet gas, and formatted mass spectra are returned digitally to a laptop.","abstract_html":"A miniature, low cost mass spectrometer has been developed that is capable of unit resolution over a mass range of 10 to 50 AMU. The design of the mass spectrometer incorporates several new features that enhance the performance of the design over comparable instruments. An efficient ion source allows a relatively low power consumption without sacrificing resolution. Variable geometry mechanical filters allow for variable resolution. An onboard ion pump removes the need for an external pumping source. An onboard digital controller allows a large degree of flexibility over the operation of the mass spectrometer while eliminating the need for high voltage electrical feedthroughs. The miniature mass spectrometer is sensitive to fractions of a percentage of inlet gas, and formatted mass spectra are returned digitally to a laptop.","abstract_has_math":false,"creators":["Hemond, Brian D. (Brian David Thomson)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Ian W. Hunter."],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011","date_published":"2011","updated_at":"2026-07-22T22:22:31Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/67584","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ian W. Hunter."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Hemond, Brian D. (Brian David Thomson)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-12-09T21:27:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-12-09T21:27:55Z"]},{"key":"dc:date.issued","label":"Date","values":["2011"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/67584"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 111-112)."]},{"key":"dc:description.abstract","label":"Abstract","values":["A miniature, low cost mass spectrometer has been developed that is capable of unit resolution over a mass range of 10 to 50 AMU. The design of the mass spectrometer incorporates several new features that enhance the performance of the design over comparable instruments. An efficient ion source allows a relatively low power consumption without sacrificing resolution. Variable geometry mechanical filters allow for variable resolution. An onboard ion pump removes the need for an external pumping source. An onboard digital controller allows a large degree of flexibility over the operation of the mass spectrometer while eliminating the need for high voltage electrical feedthroughs. The miniature mass spectrometer is sensitive to fractions of a percentage of inlet gas, and formatted mass spectra are returned digitally to a laptop."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:title","label":"Title","values":["Development and performance of a miniature, low cost mass spectrometer"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ian W. Hunter."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Hemond, Brian D. (Brian David Thomson)"],"dc:date.accessioned":["2011-12-09T21:27:55Z"],"dc:date.available":["2011-12-09T21:27:55Z"],"dc:date.issued":["2011"],"dc:description":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 111-112)."],"dc:description.abstract":["A miniature, low cost mass spectrometer has been developed that is capable of unit resolution over a mass range of 10 to 50 AMU. The design of the mass spectrometer incorporates several new features that enhance the performance of the design over comparable instruments. An efficient ion source allows a relatively low power consumption without sacrificing resolution. Variable geometry mechanical filters allow for variable resolution. An onboard ion pump removes the need for an external pumping source. An onboard digital controller allows a large degree of flexibility over the operation of the mass spectrometer while eliminating the need for high voltage electrical feedthroughs. The miniature mass spectrometer is sensitive to fractions of a percentage of inlet gas, and formatted mass spectra are returned digitally to a laptop."],"dc:description.degree":["Ph.D."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/67584"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Development and performance of a miniature, low cost mass spectrometer"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:31Z"}