Energy and first costs analysis of displacement and mixing ventilation systems for U.S. buildings and climates

Abstract

dc:description.abstract

In the past two decades, displacement ventilation has been increasingly used in Scandinavia and Western Europe to improve indoor air quality and to save energy. By using a detailed computer simulation method, this study compared the energy consumption of a displacement ventilation system with that of a mixing ventilation system for three types of U.S. buildings: a small office, a classroom and an industrial workshop. The investigation covers five U.S. climatic regions and three different building zones. The study showed that a displacement ventilation system might use more fan energy and less chiller and boiler energy than a mixing ventilation system. The total energy consumption is slightly less with a displacement ventilation system. The displacement ventilation system requires a larger air-handling unit and a smaller chiller than the mixing ventilation system does. The first costs are lower for displacement ventilation if the system is applied in the core region of a building. In the perimeter zones, the displacement ventilation system needs a separate heating system, and the first costs are slightly higher.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Architecture
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
1999

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hu, ShiPing, 1970-
Advisor dc:contributor.advisor
  • Qingyan Chen.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/67521
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/67521

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Hu, ShiPing, 1970-. Energy and first costs analysis of displacement and mixing ventilation systems for U.S. buildings and climates. Massachusetts Institute of Technology, 1999. http://hdl.handle.net/1721.1/67521