Back to results

Massachusetts Institute of Technology

Mitigation of traffic-induced bridge vibrations through passive and semi-active control devices

Abstract

dc:description.abstract

Many of the U.S. bridges today are reaching or have reached their design life and are beginning to deteriorate and are becoming structurally deficient. Much time, effort, money, and resources go into repairing, rehabilitating, or reconstructing these bridges. Therefore, investigation into valid solutions to extending the safe life of these structures is of utmost importance. A major cause of bridge deterioration is stresses and fatigue induced in the bridge from traffic loading. This paper explores and investigates methods of mitigating traffic-induced bridge vibrations through the integration of control devices to extend the service life of bridges. There are three main classes of structural control devices: passive, semi-active, and active control. Each control scheme has advantages and disadvantages which are discussed in this thesis. To gain a better understanding of both passive and semi-active control strategies, a computer simulation is conducted. The computer simulation allows for a better comparison between passive and semi-active control schemes. The finding from the simulation shows a semi-active control strategy outperforming a passive strategy. The semi-active scheme reduces maximum midspan deflections by 20%, while the passive has a reduction of 12%.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Magnuson, Amy R
Advisor dc:contributor.advisor
  • Jerome J.Connor.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/66842
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/66842

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Magnuson, Amy R. Mitigation of traffic-induced bridge vibrations through passive and semi-active control devices. Massachusetts Institute of Technology, 2011. http://hdl.handle.net/1721.1/66842