{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/66020"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/66020","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Encryption on the air : non-Invasive security for implantable medical devices","abstract":"Modern implantable medical devices (IMDs) including pacemakers, cardiac defibrillators and nerve stimulators feature wireless connectivity that enables remote monitoring and post-implantation adjustment. However, recent work has demonstrated that flawed security tempers these medical benefits. In particular, an understandable lack of cryptographic mechanisms results in the IMD disclosing private data and being unable to distinguish authorized from unauthorized commands. In this thesis, we present IMD-Shield; a prototype defenses against a previously proposed suite of attacks on IMDs. IMD-Shield is an external entity that uses a new full dulpex radio design to secure transmissions to and from the IMD on the air wihtout incorporating the IMD itself. Because replacing the install base of wireless-enabled IMDs is infeasible, our system non-invasively enhances the security of unmodified IMDs. We implement and evaluate our mechanism against modern IMDs in a variety of attack scenarios and find that it effectively provides confidentiality for private data and shields the IMD from unauthorized commands.","abstract_html":"Modern implantable medical devices (IMDs) including pacemakers, cardiac defibrillators and nerve stimulators feature wireless connectivity that enables remote monitoring and post-implantation adjustment. However, recent work has demonstrated that flawed security tempers these medical benefits. In particular, an understandable lack of cryptographic mechanisms results in the IMD disclosing private data and being unable to distinguish authorized from unauthorized commands. In this thesis, we present IMD-Shield; a prototype defenses against a previously proposed suite of attacks on IMDs. IMD-Shield is an external entity that uses a new full dulpex radio design to secure transmissions to and from the IMD on the air wihtout incorporating the IMD itself. Because replacing the install base of wireless-enabled IMDs is infeasible, our system non-invasively enhances the security of unmodified IMDs. We implement and evaluate our mechanism against modern IMDs in a variety of attack scenarios and find that it effectively provides confidentiality for private data and shields the IMD from unauthorized commands.","abstract_has_math":false,"creators":["Al-Hassanieh, Haitham (Haitham Zuhair)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.","school":null,"contributors":[],"advisors":["Dina Katabi."],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011","date_published":"2011","updated_at":"2026-07-22T22:22:15Z","subjects":["Electrical Engineering and Computer Science."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/66020","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dina Katabi."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Al-Hassanieh, Haitham (Haitham Zuhair)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-09-27T18:33:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-09-27T18:33:19Z"]},{"key":"dc:date.issued","label":"Date","values":["2011"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/66020"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2011.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 73-78)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Modern implantable medical devices (IMDs) including pacemakers, cardiac defibrillators and nerve stimulators feature wireless connectivity that enables remote monitoring and post-implantation adjustment. However, recent work has demonstrated that flawed security tempers these medical benefits. In particular, an understandable lack of cryptographic mechanisms results in the IMD disclosing private data and being unable to distinguish authorized from unauthorized commands. In this thesis, we present IMD-Shield; a prototype defenses against a previously proposed suite of attacks on IMDs. IMD-Shield is an external entity that uses a new full dulpex radio design to secure transmissions to and from the IMD on the air wihtout incorporating the IMD itself. Because replacing the install base of wireless-enabled IMDs is infeasible, our system non-invasively enhances the security of unmodified IMDs. We implement and evaluate our mechanism against modern IMDs in a variety of attack scenarios and find that it effectively provides confidentiality for private data and shields the IMD from unauthorized commands."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:title","label":"Title","values":["Encryption on the air : non-Invasive security for implantable medical devices"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dina Katabi."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:creator":["Al-Hassanieh, Haitham (Haitham Zuhair)"],"dc:date.accessioned":["2011-09-27T18:33:19Z"],"dc:date.available":["2011-09-27T18:33:19Z"],"dc:date.issued":["2011"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2011.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 73-78)."],"dc:description.abstract":["Modern implantable medical devices (IMDs) including pacemakers, cardiac defibrillators and nerve stimulators feature wireless connectivity that enables remote monitoring and post-implantation adjustment. However, recent work has demonstrated that flawed security tempers these medical benefits. In particular, an understandable lack of cryptographic mechanisms results in the IMD disclosing private data and being unable to distinguish authorized from unauthorized commands. In this thesis, we present IMD-Shield; a prototype defenses against a previously proposed suite of attacks on IMDs. IMD-Shield is an external entity that uses a new full dulpex radio design to secure transmissions to and from the IMD on the air wihtout incorporating the IMD itself. Because replacing the install base of wireless-enabled IMDs is infeasible, our system non-invasively enhances the security of unmodified IMDs. We implement and evaluate our mechanism against modern IMDs in a variety of attack scenarios and find that it effectively provides confidentiality for private data and shields the IMD from unauthorized commands."],"dc:description.degree":["S.M."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/66020"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Encryption on the air : non-Invasive security for implantable medical devices"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:15Z"}