{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/65540"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/65540","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Compton polarimeter for Qweak Experiment at Jefferson Laboratory","abstract":"The Qweak experiment at Jefferson Lab aims to make the first precision measurement of the proton's weak charge, QP = 1 - 4 sin 2 9w at Q2 = 0.026GeV 2 . Given the precision goals in the Qweak experiment, the electron beam polarization must be known to an absolute uncertainty of 1%. A new Compton polarimeter has been built and installed in Hall C in order to make this important measurement. Compton polarimetry has been chosen for its ability to deliver continuous on-line measuremnts at high currents necessary for Qweak (up to 180pzA). In this thesis, we collected and analyzed electron beam polarization data using the Qweak Compton polarimeter. Currently, data from the Compton can already be used to calculate preliminary values of experimental physics asymmetries and also the electron beam polarization. These preliminary results are promising indications that Qweak will be able to meet its stated precision goals.","abstract_html":"The Qweak experiment at Jefferson Lab aims to make the first precision measurement of the proton&#x27;s weak charge, QP = 1 - 4 sin 2 9w at Q2 = 0.026GeV 2 . Given the precision goals in the Qweak experiment, the electron beam polarization must be known to an absolute uncertainty of 1%. A new Compton polarimeter has been built and installed in Hall C in order to make this important measurement. Compton polarimetry has been chosen for its ability to deliver continuous on-line measuremnts at high currents necessary for Qweak (up to 180pzA). In this thesis, we collected and analyzed electron beam polarization data using the Qweak Compton polarimeter. Currently, data from the Compton can already be used to calculate preliminary values of experimental physics asymmetries and also the electron beam polarization. These preliminary results are promising indications that Qweak will be able to meet its stated precision goals.","abstract_has_math":false,"creators":["Zou, David"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Physics","school":null,"contributors":[],"advisors":["Stanley Kowalski."],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011","date_published":"2011","updated_at":"2026-07-22T22:22:17Z","subjects":["Physics.","Thomas Jefferson National Accelerator Facility (U.S.)"],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/65540","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Stanley Kowalski."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Thomas Jefferson National Accelerator Facility (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Zou, David"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-08-30T15:47:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-08-30T15:47:56Z"]},{"key":"dc:date.issued","label":"Date","values":["2011"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics.","Thomas Jefferson National Accelerator Facility (U.S.)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/65540"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2011.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 41-42)."]},{"key":"dc:description.abstract","label":"Abstract","values":["The Qweak experiment at Jefferson Lab aims to make the first precision measurement of the proton's weak charge, QP = 1 - 4 sin 2 9w at Q2 = 0.026GeV 2 . Given the precision goals in the Qweak experiment, the electron beam polarization must be known to an absolute uncertainty of 1%. A new Compton polarimeter has been built and installed in Hall C in order to make this important measurement. Compton polarimetry has been chosen for its ability to deliver continuous on-line measuremnts at high currents necessary for Qweak (up to 180pzA). In this thesis, we collected and analyzed electron beam polarization data using the Qweak Compton polarimeter. Currently, data from the Compton can already be used to calculate preliminary values of experimental physics asymmetries and also the electron beam polarization. These preliminary results are promising indications that Qweak will be able to meet its stated precision goals."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:title","label":"Title","values":["Compton polarimeter for Qweak Experiment at Jefferson Laboratory"]}]}],"canonical_facts":{"dc:contributor.advisor":["Stanley Kowalski."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Physics"],"dc:contributor.other":["Thomas Jefferson National Accelerator Facility (U.S.)"],"dc:creator":["Zou, David"],"dc:date.accessioned":["2011-08-30T15:47:56Z"],"dc:date.available":["2011-08-30T15:47:56Z"],"dc:date.issued":["2011"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2011.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 41-42)."],"dc:description.abstract":["The Qweak experiment at Jefferson Lab aims to make the first precision measurement of the proton's weak charge, QP = 1 - 4 sin 2 9w at Q2 = 0.026GeV 2 . Given the precision goals in the Qweak experiment, the electron beam polarization must be known to an absolute uncertainty of 1%. A new Compton polarimeter has been built and installed in Hall C in order to make this important measurement. Compton polarimetry has been chosen for its ability to deliver continuous on-line measuremnts at high currents necessary for Qweak (up to 180pzA). In this thesis, we collected and analyzed electron beam polarization data using the Qweak Compton polarimeter. Currently, data from the Compton can already be used to calculate preliminary values of experimental physics asymmetries and also the electron beam polarization. These preliminary results are promising indications that Qweak will be able to meet its stated precision goals."],"dc:description.degree":["S.B."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/65540"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Physics.","Thomas Jefferson National Accelerator Facility (U.S.)"],"dc:title":["Compton polarimeter for Qweak Experiment at Jefferson Laboratory"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:17Z"}