{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/65304"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/65304","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Advanced thermal insulation for energy efficient buildings : structural performance of aerogel composite panels","abstract":"Aerogels are well known as exceptional thermal insulators. Thermal conductivities of 9 to 10 mW/m.K have been achieved at atmospheric pressure, and a moderate vacuum (between 1/3 and 1/10 of an atmosphere) can lower this number even further, to around 5 mW/m.K. However aerogels for insulation purposes are not widespread on the market. One of the major shortcomings of aerogels that prevent them from being more widely used is their extreme mechanical weakness and brittleness. In this thesis, we characterize and explain these low mechanical properties. We then propose a composite structure for a rigid aerogel panel, a sandwich panel with a truss core filled with monolithic aerogel. Mechanical and thermal properties are derived and partially tested for the truss cores. Several designs are studied and mechanical properties are derived in order to compare these designs. Some criteria for an efficient designs are given. Finally, we describe a first attempt to manufacture one of these composite structures on a small scale.","abstract_html":"Aerogels are well known as exceptional thermal insulators. Thermal conductivities of 9 to 10 mW/m.K have been achieved at atmospheric pressure, and a moderate vacuum (between 1/3 and 1/10 of an atmosphere) can lower this number even further, to around 5 mW/m.K. However aerogels for insulation purposes are not widespread on the market. One of the major shortcomings of aerogels that prevent them from being more widely used is their extreme mechanical weakness and brittleness. In this thesis, we characterize and explain these low mechanical properties. We then propose a composite structure for a rigid aerogel panel, a sandwich panel with a truss core filled with monolithic aerogel. Mechanical and thermal properties are derived and partially tested for the truss cores. Several designs are studied and mechanical properties are derived in order to compare these designs. Some criteria for an efficient designs are given. Finally, we describe a first attempt to manufacture one of these composite structures on a small scale.","abstract_has_math":false,"creators":["Goutierre, Thomas"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Lorna J. Gibson."],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011","date_published":"2011","updated_at":"2026-07-22T22:21:56Z","subjects":["Mechanical Engineering."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/65304","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lorna J. Gibson."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Goutierre, Thomas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-08-18T19:16:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-08-18T19:16:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2011"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/65304"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 169-177)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Aerogels are well known as exceptional thermal insulators. Thermal conductivities of 9 to 10 mW/m.K have been achieved at atmospheric pressure, and a moderate vacuum (between 1/3 and 1/10 of an atmosphere) can lower this number even further, to around 5 mW/m.K. However aerogels for insulation purposes are not widespread on the market. One of the major shortcomings of aerogels that prevent them from being more widely used is their extreme mechanical weakness and brittleness. In this thesis, we characterize and explain these low mechanical properties. We then propose a composite structure for a rigid aerogel panel, a sandwich panel with a truss core filled with monolithic aerogel. Mechanical and thermal properties are derived and partially tested for the truss cores. Several designs are studied and mechanical properties are derived in order to compare these designs. Some criteria for an efficient designs are given. Finally, we describe a first attempt to manufacture one of these composite structures on a small scale."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:title","label":"Title","values":["Advanced thermal insulation for energy efficient buildings : structural performance of aerogel composite panels"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lorna J. Gibson."],"dc:contributor.department":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Goutierre, Thomas"],"dc:date.accessioned":["2011-08-18T19:16:00Z"],"dc:date.available":["2011-08-18T19:16:00Z"],"dc:date.issued":["2011"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 169-177)."],"dc:description.abstract":["Aerogels are well known as exceptional thermal insulators. Thermal conductivities of 9 to 10 mW/m.K have been achieved at atmospheric pressure, and a moderate vacuum (between 1/3 and 1/10 of an atmosphere) can lower this number even further, to around 5 mW/m.K. However aerogels for insulation purposes are not widespread on the market. One of the major shortcomings of aerogels that prevent them from being more widely used is their extreme mechanical weakness and brittleness. In this thesis, we characterize and explain these low mechanical properties. We then propose a composite structure for a rigid aerogel panel, a sandwich panel with a truss core filled with monolithic aerogel. Mechanical and thermal properties are derived and partially tested for the truss cores. Several designs are studied and mechanical properties are derived in order to compare these designs. Some criteria for an efficient designs are given. Finally, we describe a first attempt to manufacture one of these composite structures on a small scale."],"dc:description.degree":["S.M."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/65304"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Advanced thermal insulation for energy efficient buildings : structural performance of aerogel composite panels"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:56Z"}