Back to results

Massachusetts Institute of Technology

Magnetic resonance spectroscopic imaging using parallel transmission at 7T

Abstract

dc:description.abstract

Conventional magnetic resonance spectroscopic imaging (MRSI), also known as phase-encoded (PE) chemical shift imaging (CSI), suffers from both low signal-to-noise ratio (SNR) of the brain metabolites, as well as inflexible tradeoffs between acquisition time and spatial resolution. In addition, although CSI at higher main field strengths, e.g. 7 Tesla (T), offers improved SNR over clinical 1.5T or 3.OT scanners, the realization of these benefits is limited by severe inhomogeneities of the radio frequency (RF) excitation magnetic field (B,+), which is responsible for significant signal variation within the volume of interest (VOI) resulting in spatially dependent SNR losses. The work presented in this dissertation aims to provide the necessary means for using spectroscopic imaging for reliable and robust whole brain metabolite detection and quantification at high main field strengths. It addresses the challenges mentioned above by improving both the excitation and the readout components of the CSI acquisition. The long acquisition times of the PE CSI are significantly shortened (at least 20 fold) by implementing the time-efficient spiral CSI algorithm, while the B1 non-uniformities are corrected for using RF pulses designed for new RF excitation hardware at 7T, so-called parallel transmission (pTx). The B1 homogeneity of the pTx excitations improved at least by a factor of 4 (measured by the normalized spatial standard deviations) compared to conventional single channel transmit systems. The first contribution of this thesis describes the implementation of spiral CSI algorithm for online gradient waveform design and spectroscopic image reconstruction with standard clinical excitation protocols and applied in studies of Late-Onset Tay- Sachs (LOTS), adrenoleukodystrophy (ALD) and brain tumors. A major contribution of this thesis is pTx excitation design for CSI to provide spectral-spatial mitigation of the B1+ inhomogeneities at 7T. Novel pTx RF designs are proposed and demonstrated to yield excellent flip angle mitigation of the brain metabolites, and also enable improved suppression of the undesired water and lipid signals. A major obstacle to the deployment of 7T pTx applications for clinical imaging is the monitoring and management of local specific absorption rate (SAR). This thesis also proposes a pTx SAR monitoring system with real-time RF monitoring and shut-off capabilities.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gagoski, Borjan Aleksandar
Advisor dc:contributor.advisor
  • Elfar Adalsteinsson.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/63069
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/63069

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Gagoski, Borjan Aleksandar. Magnetic resonance spectroscopic imaging using parallel transmission at 7T. Massachusetts Institute of Technology, 2011. http://hdl.handle.net/1721.1/63069